Literature DB >> 6375596

Aortic and mitral valve replacement with the St. Jude Medical prosthesis.

F A Crawford, J M Kratz, R M Sade, M R Stroud, D M Bartles.   

Abstract

From April 1, 1979 to August 31, 1983, 228 patients underwent isolated aortic (AVR) (118) or mitral (MVR) (90) valve replacements with a new tilting disc valve prosthesis, the St. Jude prosthesis, at the Medical University of South Carolina. Age ranged from 6 to 84 years (mean 49.1 +/- 19.2 AVR, 44.5 +/- 16.5 MVR). Male sex predominated in the AVR group (68%) and female sex in the MVR group (68%). Thirty-five patients (16.8%) had associated coronary bypass surgery (AVR 23.7%, MVR 7.8%). There were seven deaths (3.4%) occurring during the same hospitalization (AVR: 3/118, 2.5%; MVR: 4/90, 4.4%). Follow-up is 97.6% complete and ranges from 1 to 54 months (mean 19.6 +/- 12.4). In the AVR group, nine late deaths have occurred and actuarial survival at 42 months is 86.7 +/- 3.8%. Three patients have sustained thromboembolic episodes for a linearized rate of 1.6% patient-year, and the probability of remaining free of thromboembolism at 42 months is 96.9 +/- 1.8%. The mean improvement in functional class from preoperative to postoperative is 3.1 +/- 0.7 to 1.2 +/- 0.4 (p less than 0.001). In the MVR group, there have been four late deaths, and the actuarial survival at 42 months is 89.3 +/- 3.8%. Two patients have sustained thromboembolic complications for a linearized rate of 1.2%/patient-year, and the probability of remaining free of thromboembolism at 42 months is 97.2 +/- 2%. The mean improvement in functional class from before to after surgery is 3.2 +/- 0.7 to 1.3 +/- 0.5 (p less than 0.001). There have been no thromboses of the St. Jude valve in the mitral or aortic position, no mechanical failures, and no patient has had significant valve-related hemolysis. Because of this experience, the St. Jude Medical heart valve prosthesis is our prosthesis of choice for any patient undergoing valve replacement with a mechanical prosthesis.

Entities:  

Mesh:

Year:  1984        PMID: 6375596      PMCID: PMC1353462          DOI: 10.1097/00000658-198406000-00014

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  23 in total

1.  Ten to fifteen year reassessment of the performance characteristics of the Starr-Edwards Model 6120 mitral valve prosthesis.

Authors:  D C Miller; P E Oyer; E B Stinson; B A Reitz; S W Jamieson; W A Baumgartner; R S Mitchell; N E Shumway
Journal:  J Thorac Cardiovasc Surg       Date:  1983-01       Impact factor: 5.209

2.  Fatal thrombosis of an aortic St. Jude Medical valve despite "adequate" anticoagulation: anatomic and technical considerations.

Authors:  A L Moulton; R T Singleton; W F Oster; J Bosley; W Mergner
Journal:  J Thorac Cardiovasc Surg       Date:  1982-03       Impact factor: 5.209

3.  In vivo radiographic appearance of the St. Jude valve prosthesis.

Authors:  W Castaneda-Zuniga; D Nicoloff; C Jorgensen; P H Nath; C Zollikofer; K Amplatz
Journal:  Radiology       Date:  1980-03       Impact factor: 11.105

4.  Echocardiographic features of the correctly functioning St. Jude Medical valve prosthesis.

Authors:  F W Amann; D Burckhardt; J Hasse; E Grädel
Journal:  Am Heart J       Date:  1981-01       Impact factor: 4.749

5.  Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus.

Authors:  D C Wortham; T B Tri; T E Bowen
Journal:  J Thorac Cardiovasc Surg       Date:  1981-04       Impact factor: 5.209

6.  Flow characteristics of the St. Jude prosthetic valve: an in vitro and in vivo study.

Authors:  A P Yoganathan; A Chaux; R J Gray; M De Robertis; J M Matloff
Journal:  Artif Organs       Date:  1982-08       Impact factor: 3.094

7.  Thrombosis of a St. Jude Medical tricuspid prosthesis. Case report.

Authors:  T E Bowen; T B Tri; D C Wortham
Journal:  J Thorac Cardiovasc Surg       Date:  1981-08       Impact factor: 5.209

8.  An appreciation of the new St. Jude valvular prosthesis.

Authors:  A Chaux; R J Gray; J M Matloff; H Feldman; H Sustaita
Journal:  J Thorac Cardiovasc Surg       Date:  1981-02       Impact factor: 5.209

9.  Late results after mitral valve replacement with the Björk-Shiley and porcine prostheses.

Authors:  W G Marshall; N T Kouchoukos; R B Karp; J B Williams
Journal:  J Thorac Cardiovasc Surg       Date:  1983-06       Impact factor: 5.209

10.  Clinical and hemodynamic results with the St. Jude Medical cardiac valve prosthesis. A three-year experience.

Authors:  D M Nicoloff; R W Emery; K V Arom; W F Northrup; C R Jorgensen; Y Wang; W G Lindsay
Journal:  J Thorac Cardiovasc Surg       Date:  1981-11       Impact factor: 5.209

View more
  1 in total

Review 1.  Drug treatment associated with heart valve replacement.

Authors:  D S Coulshed; M A Fitzpatrick; C H Lee
Journal:  Drugs       Date:  1995-06       Impact factor: 9.546

  1 in total