Literature DB >> 7438386

Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance.

J P Murgo, N Westerhof, J P Giolma, S A Altobelli.   

Abstract

Dramatic changes in the shape of pulsatile ascending aortic pressure and flow wave forms occur during the Valsalva maneuver in man. To study these changes, aortic pressure and flow signals were recorded in eight patients using a multisensor catheter. Aortic input impedance was derived during the control, strain and postrelease phases of the Valsalva maneuver. During control, well-defined minima and maxima occurred in the spectral plots of impedance moduli. This pattern was accentuated during the postrelease phase. In contrast, input impedance during strain was almost equal to the characteristic impedance for all harmonics. These results imply that during the control and postrelease phases, strong reflections return to the ascending aorta, but during the strain phase, reflections are minimal, absent or more diffuse. From wave transmission theory, it also follows that pulsatile pressure and flow wave forms should be similar in shape in the absence of reflections and dissimilar in the presence of reflections. This was observed in all eight patients. By provoking changes in the arterial tree during the Valsalva maneuver, the magnitude and timing of wave reflections were significantly altered, resulting in marked changes in the shape of pulsatile aortic pressure and flow wave forms. This study demonstrates the importance of reflections in determining the shape of the arterial pulse.

Entities:  

Mesh:

Year:  1981        PMID: 7438386     DOI: 10.1161/01.cir.63.1.122

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  24 in total

1.  Doppler continuous-wave analysis of grafted mammary artery as a non-invasive technique for static and dynamic assessment of coronary flow in man.

Authors:  M Ciccone; A Federici; L di Michele; A Marchese; A Chiddo; P Rizzon
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1990

Review 2.  Time domain analysis of the arterial pulse in clinical medicine.

Authors:  Michael F O'Rourke
Journal:  Med Biol Eng Comput       Date:  2008-07-15       Impact factor: 2.602

3.  Influence of pleural pressure variations on cardiovascular system dynamics: a model study.

Authors:  Y Goldstein; R Beyar; S Sideman
Journal:  Med Biol Eng Comput       Date:  1988-05       Impact factor: 2.602

4.  CrossTalk proposal: Forward and backward pressure waves in the arterial system do represent reality.

Authors:  Nico Westerhof; Berend E Westerhof
Journal:  J Physiol       Date:  2013-03-01       Impact factor: 5.182

5.  Technique of micromanometric catheterization of the descending aorta in man: a method to study regional arterial dynamics.

Authors:  R D Latham
Journal:  Heart Vessels       Date:  1987       Impact factor: 2.037

6.  Assessment of algorithms used to compute the fast Fourier transform of left ventricular pressure on a microcomputer.

Authors:  A E Marble; J W Ashe; D H Tsang; D Belliveau; D N Swingler
Journal:  Med Biol Eng Comput       Date:  1985-03       Impact factor: 2.602

7.  Arterial windkessel parameter estimation: a new time-domain method.

Authors:  Y Shim; A Pasipoularides; C A Straley; T G Hampton; P F Soto; C H Owen; J W Davis; D D Glower
Journal:  Ann Biomed Eng       Date:  1994 Jan-Feb       Impact factor: 3.934

8.  Differential vascular reactivity responses acutely following ingestion of a nitrate rich red spinach extract.

Authors:  Cody T Haun; Wesley C Kephart; Angelia M Holland; Christopher B Mobley; Anna E McCloskey; Joshua J Shake; David D Pascoe; Michael D Roberts; Jeffrey S Martin
Journal:  Eur J Appl Physiol       Date:  2016-09-30       Impact factor: 3.078

9.  Arterial hemodynamics in human hypertension.

Authors:  C T Ting; K P Brin; S J Lin; S P Wang; M S Chang; B N Chiang; F C Yin
Journal:  J Clin Invest       Date:  1986-12       Impact factor: 14.808

10.  Comparison of arterial waves derived by classical wave separation and wave intensity analysis in a model of aortic coarctation.

Authors:  Jeroen P H M van den Wijngaard; Maria Siebes; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-09-02       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.