Literature DB >> 741206

Raynaud phenomena and finger systolic pressure during cooling.

S L Nielsen.   

Abstract

Finger systolic pressure (FSP) can be measured after finger cooling with a water perfused double-inlet-plastic cuff on the midphalanx of a finger and a mercury-in-rubber strain gauge on the outer phalanx. After finger cooling to 20, 15 and 10 degree C eighteen females with primary Raynaud phenomena had a significantly greater reduction in FSP than twenty-two normal females, but only eleven of the eighteen females (60%) with Raynaud phenomena showed digital arterial closure. Standardized body cooling for 20 min before finger cooling enhanced the reaction in both groups. As only females with Raynaud phenomena showed digital artery closure, the diagnostic value of a combined finger and body cooling test in primary Raynaud phenomena is high. The reproducibility of the test is acceptable.

Entities:  

Mesh:

Year:  1978        PMID: 741206     DOI: 10.1080/00365517809104885

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  26 in total

1.  Vibration exposure, smoking, and vascular dysfunction.

Authors:  M Cherniack; J Clive; A Seidner
Journal:  Occup Environ Med       Date:  2000-05       Impact factor: 4.402

2.  Skin temperature recovery from cold provocation in workers exposed to vibration: a longitudinal study.

Authors:  M Cherniack; A Brammer; J Meyer; T Morse; D Peterson; R Fu
Journal:  Occup Environ Med       Date:  2003-12       Impact factor: 4.402

3.  Effect of room temperature on percentage finger systolic blood pressure response to finger cooling.

Authors:  M S Laskar; K Ohmura; M Inoue; K Yokoyama; J Inagaki; Y Takahashi; M H Mahbub; H Ohnari; N Harada
Journal:  Eur J Appl Physiol       Date:  2005-06-01       Impact factor: 3.078

Review 4.  Pathogenesis and treatment of Raynaud's phenomenon.

Authors:  J D Coffman
Journal:  Cardiovasc Drugs Ther       Date:  1990-01       Impact factor: 3.727

Review 5.  Quantifying digital vascular disease in patients with primary Raynaud's phenomenon and systemic sclerosis.

Authors:  A L Herrick; S Clark
Journal:  Ann Rheum Dis       Date:  1998-02       Impact factor: 19.103

6.  Standardization of finger systolic blood pressure (FSBP) cooling tests.

Authors:  Niels Olsen
Journal:  Environ Health Prev Med       Date:  2005-11       Impact factor: 3.674

7.  Factors influencing finger systolic blood pressure test for diagnosis of vibration-induced white finger.

Authors:  Youichi Kurozawa; Yoshiro Nasu
Journal:  Environ Health Prev Med       Date:  2005-11       Impact factor: 3.674

8.  Development of noninvasive measurement of peripheral circulation and its medical application.

Authors:  H Nakamura
Journal:  Environ Health Prev Med       Date:  1997-04       Impact factor: 3.674

9.  Test battery for assessing vascular disturbances of fingers.

Authors:  Christopher J Lindsell
Journal:  Environ Health Prev Med       Date:  2005-11       Impact factor: 3.674

10.  Vibration white finger: a follow up study.

Authors:  L Ekenvall; A Carlsson
Journal:  Br J Ind Med       Date:  1987-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.