Literature DB >> 15928934

Effect of room temperature on percentage finger systolic blood pressure response to finger cooling.

M S Laskar1, K Ohmura, M Inoue, K Yokoyama, J Inagaki, Y Takahashi, M H Mahbub, H Ohnari, N Harada.   

Abstract

Percentage finger systolic blood pressure (%FSBP) in response to finger cooling is used to assess vascular components of the hand-arm vibration syndrome and the measurement method is under discussion for standardization. It has been suggested that measurement circumstances including room temperature may affect %FSBP. We investigated the effect of room temperature on %FSBP response to finger cooling in healthy subjects. Six healthy male subjects who were medical students volunteered for the study. Multi-channel plethysmograph was used for simultaneous multi-finger FSBP measurements. The examination room was kept at 21 +/- 1 degrees C and 25 +/- 1 degrees C, and the subjects were randomly assigned. Percentage finger systolic blood pressures for the index, middle, ring and little fingers at 15 degrees C and 10 degrees C cuff-water temperatures were calculated. Four-way analysis of variance was performed to determine the independent effect of subject, room temperature, finger and cuff-water temperature factors on %FSBP. The room temperature as an independent factor affecting %FSBP was statistically significant (P < 0.01). From the results, it can be concluded that %FSBP response to finger cooling in healthy subjects may be affected by room temperature. Therefore, room temperature is expected to be controlled when assessing peripheral vascular components of the upper extremities using %FSBP response to finger cooling.

Entities:  

Mesh:

Year:  2005        PMID: 15928934     DOI: 10.1007/s00421-005-1363-y

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  21 in total

1.  Finger systolic blood pressure indices for the diagnosis of vibration-induced white finger.

Authors:  Massimo Bovenzi
Journal:  Int Arch Occup Environ Health       Date:  2002-01       Impact factor: 3.015

Review 2.  Diagnostic aspects of vibration-induced white finger.

Authors:  Niels Olsen
Journal:  Int Arch Occup Environ Health       Date:  2002-01       Impact factor: 3.015

3.  Finger blood pressure and rewarming rate for screening and diagnosis of Raynaud's phenomenon in workers exposed to vibration.

Authors:  H Virokannas; H Rintamäki
Journal:  Br J Ind Med       Date:  1991-07

4.  Vibration-induced white finger and cold response of digital arterial vessels in occupational groups with various patterns of exposure to hand-transmitted vibration.

Authors:  M Bovenzi
Journal:  Scand J Work Environ Health       Date:  1998-04       Impact factor: 5.024

5.  Clinical studies of the vibration syndrome using a cold stress test measuring finger temperature.

Authors:  M Gautherie
Journal:  Cent Eur J Public Health       Date:  1995       Impact factor: 1.163

6.  Vibration frequencies and amplitudes in the aetiology of traumatic vasospastic disease.

Authors:  J Hyvärinen; I Pyykkö; S Sundberg
Journal:  Lancet       Date:  1973-04-14       Impact factor: 79.321

7.  Vibration-induced hyperresponsiveness of arterial smooth muscle to noradrenaline with special reference to Raynaud's phenomenon in vibration disease.

Authors:  T Azuma; T Ohhashi; M Sakaguchi
Journal:  Cardiovasc Res       Date:  1978-12       Impact factor: 10.787

8.  [Effects of immersion of hand in cold water (10 degrees C for 10 min) on the finger skin temperature of chain saw operators under different room temperatures (author's transl)].

Authors:  N Kurumatani; K Ogoshi; Y Aoki; T Moriyama; S Tomii
Journal:  Sangyo Igaku       Date:  1981-05

9.  Cold response of digital arteries in chain saw operators.

Authors:  N Olsen; S L Nielsen; P Voss
Journal:  Br J Ind Med       Date:  1982-02

10.  The diagnosis of disorders caused by hand-transmitted vibration: Southampton Workshop 2000.

Authors:  Michael J Griffin; Massimo Bovenzi
Journal:  Int Arch Occup Environ Health       Date:  2002-01       Impact factor: 3.015

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.