Literature DB >> 7398015

Pulsed doppler echocardiographic measurement of beat-to-beat changes in stroke volume in dogs.

R M Steingart, J Meller, J Barovick, R Patterson, M V Herman, L E Teichholz.   

Abstract

Measurement of stroke volume by pulsed Doppler echocardiography has not been validated against a reference method in vivo. We compared Doppler systolic frequency shift integrals with electromagnetic flowmeter stroke volume in seven open-chest dogs. A pulsed Doppler echocardiographic transducer was held on the aortic arch with the sample volume in the ascending aorta. Stroke volume was varied by epinephrine or pentobarbital infusions, fluid administration or inferior vena caval construction. Linear regression analysis of stroke volume vs Doppler systolic frequency shift integrals revealed strong correlations and intercepts close to zero (tau = 0.74-0.096, rho less than 0.001). Minor changes in transducer position did not influence Doppler frequency shift integrals substantially. Therefore, pulsed Doppler echocardiography served as an excellent measurement of stroke volume changes in model. However, serious limitations are presented that may limit its clinical application.

Entities:  

Mesh:

Year:  1980        PMID: 7398015     DOI: 10.1161/01.cir.62.3.542

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  6 in total

Review 1.  Doppler echocardiography for the estimation of cardiac output with exercise.

Authors:  Thomas Rowland; Philippe Obert
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Anisotropic reinforcement of acute anteroapical infarcts improves pump function.

Authors:  Gregory M Fomovsky; Samantha A Clark; Katherine M Parker; Gorav Ailawadi; Jeffrey W Holmes
Journal:  Circ Heart Fail       Date:  2012-06-04       Impact factor: 8.790

3.  Ultrasonic flowmeter with implantable miniature sensors.

Authors:  T Nakamura; K Hayashi; Y Taenaka; M Umezu; T Nakatani; H Takano
Journal:  Med Biol Eng Comput       Date:  1986-05       Impact factor: 2.602

Review 4.  Assessment of cardiac hemodynamics and valvular function by Doppler echocardiography.

Authors:  D C Wallerson; J Dubin; R B Devereux
Journal:  Bull N Y Acad Med       Date:  1987-10

5.  Determination of cardiac output by Doppler echocardiography.

Authors:  H Ihlen; J P Amlie; J Dale; K Forfang; S Nitter-Hauge; J E Otterstad; S Simonsen; E Myhre
Journal:  Br Heart J       Date:  1984-01

Review 6.  Clinical diagnosis by transcutaneous Doppler ultrasound.

Authors:  R K Wyse
Journal:  Postgrad Med J       Date:  1982-04       Impact factor: 2.401

  6 in total