Literature DB >> 7379330

The use of C1q, conglutinin and low affinity rabbit IgM antibody to human Fc in a ligand coctail radioassay for detecting and characterizing immune complexes in pathological sera.

G D Harkiss, D L Brown.   

Abstract

A ligand radioassay for the detection of IC which utilizes C1q, bovine conglutinin and low affinity rabbit IgM anti-human Fc in a reagent coctail, is presented. IC are first isolated from serum by precipitation in polyethylene glycol, then analysed for their ability to react with the ligand coctail. Dual-label studies with 125I and 131I-tagged ligands, designed to determine whether the ligands bound independently to IC, indicate that the binding of each ligand to IC is not significantly affected by the presence of the other two ligands. The results of assaying pathological sera for IC by the ligand coctail radioassay correlate well with the results of three other assays. The assay system is also flexible enough to allow other low affinity IgM reagents to be used which could potentially cover the whole range of immunoglobulin classes occurring in pathological IC.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7379330      PMCID: PMC1538118     

Source DB:  PubMed          Journal:  Clin Exp Immunol        ISSN: 0009-9104            Impact factor:   4.330


  17 in total

1.  Preparation of iodine-131 labelled human growth hormone of high specific activity.

Authors:  W M HUNTER; F C GREENWOOD
Journal:  Nature       Date:  1962-05-05       Impact factor: 49.962

2.  Clq: rapid purification method for preparation of monospecific antisera and for biochemical studies.

Authors:  K Yonemasu; R M Stroud
Journal:  J Immunol       Date:  1971-02       Impact factor: 5.422

Review 3.  Detection of immune complexes in human diseases.

Authors:  R H Zubler; P H Lambert
Journal:  Prog Allergy       Date:  1978

4.  Detection of immune complexes by a new assay, the polyethylene glycol precipitation-complement consumption test (PEG-CC).

Authors:  G D Harkiss; D L Brown
Journal:  Clin Exp Immunol       Date:  1979-04       Impact factor: 4.330

5.  Conglutinin binding polyethylene glycol precipitation assay for immune complexes.

Authors:  M Macanovic; P J Lachmann
Journal:  Clin Exp Immunol       Date:  1979-11       Impact factor: 4.330

6.  Immune complexes in sera and synovial fluids of patients with rheumatoid arthritis. Radioimmunoassay with monocylonal rheumatoid factor.

Authors:  H S Luthra; F C McDuffie; G G Hunder; E A Samayoa
Journal:  J Clin Invest       Date:  1975-08       Impact factor: 14.808

7.  Detection of immune complexes in unheated sera by modified 125I-Clq binding test. Effect of heating on the binding of Clq by immune complexes and application of the test to systemic lupus erythematosus.

Authors:  R H Zubler; G Lange; P H Lambert; P A Miescher
Journal:  J Immunol       Date:  1976-01       Impact factor: 5.422

8.  Circulating immune complexes in the serum in systemic lupus erythematosus and in carriers of hepatitis B antigen. Quantitation by binding to radiolabeled C1q.

Authors:  U E Nydegger; P H Lambert; H Gerber; P A Miescher
Journal:  J Clin Invest       Date:  1974-08       Impact factor: 14.808

9.  Ultracentifuge studies of the binding of IgG of different subclasses to the Clq subunit of the first component of complement.

Authors:  V N Schumaker; M A Calcott; H L Spiegelberg; H J Müller-Eberhard
Journal:  Biochemistry       Date:  1976-11-16       Impact factor: 3.162

10.  Circulating immune complexes in steroid-responsive nephrotic syndrome.

Authors:  R J Levinsky; P N Malleson; T M Barratt; J F Soothill
Journal:  N Engl J Med       Date:  1978-01-19       Impact factor: 91.245

View more