Literature DB >> 7349927

Accuracy and reproducibility of new M-mode echocardiographic recommendations for measuring left ventricular dimensions.

M H Crawford, D Grant, R A O'Rourke, M R Starling, B M Groves.   

Abstract

In order to assess the accuracy and reproducibility of the proposed American Society of Echocardiography (ASE) method for measuring left ventricular dimensions on M-mode echocardiograms, we measured the end-diastolic (Dd) and end-systolic (Ds) dimensions by the ASE method and our current technique in 50 normal subjects and 24 patients without coronary artery disease who had symmetrically contracting ventricles on cineangiography. Dd and Ds were significantly greater by the proposed ASE method than by our current technique (p less than 0.001), but the correlation between the two was good (r = 0.93 and 0.83, respectively). In 10 of the normal subjects, the interobserver variability of both methods was excellent. In the 24 patients, the proposed method consistently overestimated the angiographic left ventricular volumes compared with our current technique and occasionally the discrepancies were quite large. Therefore, the proposed ASE method for measuring left ventricular dimensions is not clearly superior to other currently available techniques.

Entities:  

Mesh:

Year:  1980        PMID: 7349927     DOI: 10.1161/01.cir.61.1.137

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  6 in total

1.  Left ventricular hypertrophy reversal with labetalol and propranolol: a prospective randomized, double-blind study.

Authors:  J Szlachcic; W D Hall; J F Tubau; V Porter; C Vollmer; G Wollam; A Hirsch; B Massie
Journal:  Cardiovasc Drugs Ther       Date:  1990-04       Impact factor: 3.727

2.  A haemodynamic and pharmacokinetic study to assess a new transdermal nitroglycerin preparation in normal subjects.

Authors:  E D Bennett; A L Davis
Journal:  Eur J Clin Pharmacol       Date:  1984       Impact factor: 2.953

3.  Normal serial variability for M-mode and digitized echocardiography in a pediatric population.

Authors:  G G Sandor; P Schumacher; M L Puterman; R Popov
Journal:  Pediatr Cardiol       Date:  1987       Impact factor: 1.655

4.  The heart in Portuguese amyloidosis.

Authors:  A F de Freitas
Journal:  Postgrad Med J       Date:  1986-06       Impact factor: 2.401

5.  Left ventricle remodeling predicts the recurrence of ventricular tachyarrhythmias in implantable cardioverter defibrillator recipients for secondary prevention.

Authors:  Wei-Chieh Lee; Huang-Chung Chen; Yung-Lung Chen; Tzu-Hsien Tsai; Kuo-Li Pan; Yu-Sheng Lin; Mien-Cheng Chen
Journal:  BMC Cardiovasc Disord       Date:  2016-11-21       Impact factor: 2.298

6.  Comparison of ventricular tachyarrhythmia recurrence between ischemic cardiomyopathy and dilated cardiomyopathy: a retrospective study.

Authors:  Chih-Yuan Fang; Huang-Chung Chen; Yung-Lung Chen; Tzu-Hsien Tsai; Kuo-Li Pan; Yu-Sheng Lin; Mien-Cheng Chen; Wei-Chieh Lee
Journal:  PeerJ       Date:  2018-07-16       Impact factor: 2.984

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.