Normal serial variability for M-mode and digitized echocardiography in a pediatric population.

G G Sandor, P Schumacher, M L Puterman, R Popov.   

Abstract

The normal serial variability of M-mode and digitized echocardiography was assessed in 18 healthy children aged 3-16 years. M-mode echocardiograms were done one month apart in each child and two sets of three beats were analyzed twice for each month's tracing. Ejection fraction and shortening fraction were obtained in the standard manner and the tracing digitized and analyzed for peak and normalized left ventricular velocities, and for posterior wall and septal wall velocities in systole and diastole. The component variabilities were determined by a univariate four-factor hierarchical variance components analysis and the sum of these variability limits established. Standard M-mode echocardiographic measurements of shortening fraction and ejection fraction (15% and 10% of mean) were the least variable. Peak and normalized velocities were more variable with left ventricular velocities (18%-29% of mean), posterior wall velocities (26%-45% of mean) and septal velocities (38%-68% of mean) showing increasing variabilities. Thus there is less variability in M-mode echocardiography than digitized echocardiography. The normal limits of variability are established and should be used for follow-up studies.

Entities:  

Mesh:

Year:  1987        PMID: 3601733     DOI: 10.1007/BF02308380

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  25 in total

1.  Great vessel, cardiac chamber, and wall growth patterns in normal children.

Authors:  M L Epstein; S J Goldberg; H D Allen; L Konecke; J Wood
Journal:  Circulation       Date:  1975-06       Impact factor: 29.690

2.  Evaluation of left ventricular size and function by echocardiography. Results in normal children.

Authors:  H P Gutgesell; M Paquet; D F Duff; D G McNamara
Journal:  Circulation       Date:  1977-09       Impact factor: 29.690

3.  Determination of left ventricular volumes by ultrasound.

Authors:  N J Fortun; W P Hood; M E Sherman; E Craige
Journal:  Circulation       Date:  1971-10       Impact factor: 29.690

4.  Left ventricular volumes and ejection fraction by echocardiography.

Authors:  J F Pombo; B L Troy; R O Russell
Journal:  Circulation       Date:  1971-04       Impact factor: 29.690

5.  Precision of digitized M-mode echocardiograms for clinical practice.

Authors:  R E Bullock; D Appleton; C Griffiths; C J Albers; H Amer; R J Hall
Journal:  Eur Heart J       Date:  1984-11       Impact factor: 29.983

6.  Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.

Authors:  D J Sahn; A DeMaria; J Kisslo; A Weyman
Journal:  Circulation       Date:  1978-12       Impact factor: 29.690

7.  Sources of variability in echocardiographic measurements.

Authors:  J M Felner; B A Blumenstein; R C Schlant; A D Carter; B N Alimurung; M J Johnson; S W Sherman; M W Klicpera; M H Kutner; L W Drucker
Journal:  Am J Cardiol       Date:  1980-05       Impact factor: 2.778

8.  Computer analysis of cardiac contractility variables obtained by M-mode echocardiography in normal newborns.

Authors:  R Hofstetter; A Mayr; G von Bernuth
Journal:  Br Heart J       Date:  1982-12

9.  Serial measurements of left ventricular dimensions by echocardiography. Assessment of week-to-week, inter- and intraobserver variability in normal subjects and patients with valvular heart disease.

Authors:  G O Ladipo; F G Dunn; T H Pringle; B Bastian; T D Lawrie
Journal:  Br Heart J       Date:  1980-09

10.  Reproducibility of echocardiography in chronic congestive heart failure.

Authors:  D V Unverferth; R P Lewis; C V Leier; R D Magorien; P K Fulkerson
Journal:  J Clin Ultrasound       Date:  1980-12       Impact factor: 0.910

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.