Literature DB >> 7348699

Effects of roughness on the thrombogenicity of a plastic.

J F Hecker, R O Edwards.   

Abstract

Tubings extruded from one batch of polyvinylchloride resin at five temperatures ranging from 110 to 205 degrees C were tested for thrombogenicity in the saphenous vein and aorta of sheep. There was more thrombus in both the vein and aorta on tubings extruded at lower temperatures. The surface areas of renal infarction were smaller when lower temperature tubings were inserted into the aorta. Scanning electron microscopy showed that lower extrusion temperatures caused greater roughness on the tubings. This greater roughness was confirmed by roughness measurements. It is suggested that the association which has been demonstrated between roughness and thrombus formation might be due to the degree of adhesion of the thrombus to the surface rather than to differences in thrombogenicity.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7348699     DOI: 10.1002/jbm.820150104

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  7 in total

Review 1.  Tissue Engineering at the Blood-Contacting Surface: A Review of Challenges and Strategies in Vascular Graft Development.

Authors:  Daniel Radke; Wenkai Jia; Dhavan Sharma; Kemin Fena; Guifang Wang; Jeremy Goldman; Feng Zhao
Journal:  Adv Healthc Mater       Date:  2018-05-07       Impact factor: 9.933

Review 2.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

Review 3.  Intravenous fluid therapy in calves.

Authors:  R R Tremblay
Journal:  Vet Clin North Am Food Anim Pract       Date:  1990-03       Impact factor: 3.357

4.  Electrokinetic and hemostatic profiles of nonwoven cellulosic/synthetic fiber blends with unbleached cotton.

Authors:  J Vincent Edwards; Elena Graves; Alvin Bopp; Nicolette Prevost; Michael Santiago; Brian Condon
Journal:  J Funct Biomater       Date:  2014-11-28

5.  Load-bearing biomedical applications of diamond-like carbon coatings - current status.

Authors:  Esa Alakoski; Veli-Matti Tiainen; Antti Soininen; Yrjö T Konttinen
Journal:  Open Orthop J       Date:  2008-03-26

Review 6.  Obstacles in haemocompatibility testing.

Authors:  W van Oeveren
Journal:  Scientifica (Cairo)       Date:  2013-05-07

Review 7.  Control of Blood Coagulation by Hemocompatible Material Surfaces-A Review.

Authors:  Janna Kuchinka; Christian Willems; Dmitry V Telyshev; Thomas Groth
Journal:  Bioengineering (Basel)       Date:  2021-12-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.