Literature DB >> 7341510

Mechanical testing of trabecular bone in knee replacement.

O Sneppen, P Christensen, H Larsen, P S Vang.   

Abstract

To measure the strength of the juxta-articular trabecular bone in knee replacement, an osteopenetrometer was developed. The principle of its function is tha a needle penetrates the bony tissue and during this penetration the pressure on and the displacement of the needle is registered. The instrument was tested on cadaveric specimens of the proximal tibia. Good agreement was found between the osteopenetrometer findings in 18 cases and compression tests on the same bony structure. Forty-five measurements at different sites of the tibial resection surface revealed that the force needed for the penetration varied according to a pattern known from the determination of the elasticity modulus and ultimate compressive strength of bone in the same area. Histological examination of the penetration canals in the bone disclosed only sparse upsetting of bone. Curves from corresponding bone proved to reflect, in height as well as shape, the morphology of the skeletal structure. The osteopenetrometer appears to be applicable fo objectively assessing the solidity of trabecular bone during the operation. Thereby it is possible, in each individual case, to form a basis for more varied planning of the postoperative treatment programme.

Mesh:

Year:  1981        PMID: 7341510     DOI: 10.1007/bf00271079

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  2 in total

1.  Bone mineral content in the proximal tibia measured by computer tomography.

Authors:  B Liliequist; S E Larsson; I Sjögren; G Wickman; K Wing
Journal:  Acta Radiol Diagn (Stockh)       Date:  1979

2.  Mechanical tests on the tibial components of non-hinged knee prostheses.

Authors:  J H Bargren; W H Day; M A Freeman; S A Swanson
Journal:  J Bone Joint Surg Br       Date:  1978-05
  2 in total
  10 in total

1.  Posteriorly stabilised (Insall-Burstein) total condylar knee arthroplasty. A follow-up study of 157 knees.

Authors:  D V Patel; P M Aichroth; J S Wand
Journal:  Int Orthop       Date:  1991       Impact factor: 3.075

2.  Tibial component in total knee arthroplasty: To cement or not to cement?

Authors:  P Cherubino; C Castelli; F A Grassi
Journal:  Eur J Orthop Surg Traumatol       Date:  1996-02

3.  Bone strength measurements at the proximal tibia. Penetration tests and epiphyseal compressive strength.

Authors:  I Hvid; J Jensen; S Nielsen
Journal:  Int Orthop       Date:  1986       Impact factor: 3.075

4.  Dual-photon absorptiometry of the proximal tibia.

Authors:  I Hvid; C Hasling; S L Hansen; H H Hansen
Journal:  Arch Orthop Trauma Surg       Date:  1987

5.  Quantitative morphology of the subchondral plate of the tibial plateau.

Authors:  S Milz; R Putz
Journal:  J Anat       Date:  1994-08       Impact factor: 2.610

6.  Tibial plateau strength patterns in experimental modular knee replacement.

Authors:  I Hvid; J T Møller
Journal:  Arch Orthop Trauma Surg       Date:  1985

7.  Cancellous bone at the knee: a comparison of two methods of strength measurement.

Authors:  I Hvid
Journal:  Arch Orthop Trauma Surg       Date:  1985

8.  Standardizing compression testing for measuring the stiffness of human bone.

Authors:  S Zhao; M Arnold; S Ma; R L Abel; J P Cobb; U Hansen; O Boughton
Journal:  Bone Joint Res       Date:  2018-09-15       Impact factor: 5.853

9.  Regional apparent density correlations within the proximal humerus.

Authors:  Jacob M Reeves; Tom Vanasse; Chris Roche; George S Athwal; James A Johnson; Kenneth J Faber; G Daniel G Langohr
Journal:  JSES Int       Date:  2021-02-09

10.  Correction of coronal alignment correlates with reconstruction of joint height in unicompartmental knee arthroplasty.

Authors:  U Kuwashima; K Okazaki; Y Tashiro; H Mizu-Uchi; S Hamai; S Okamoto; K Murakami; Y Iwamoto
Journal:  Bone Joint Res       Date:  2015-08       Impact factor: 5.853

  10 in total