Literature DB >> 3804529

Bone strength measurements at the proximal tibia. Penetration tests and epiphyseal compressive strength.

I Hvid, J Jensen, S Nielsen.   

Abstract

Three penetration tests were obtained from corresponding locations at each condyle of 19 proximal tibiae. The patterns of condylar cancellous bone strength varied little between knees. The medial condyle was the strongest with an average medial to lateral strength ratio of 1.9, and in most knees the medial condyle was strongest centrally while the lateral condyle was strongest posteriorly. The penetration strength at 5 successive 2 mm levels beneath the resected subchondral surface also showed a constant pattern of variation. Bone strength decreased significantly at first except at the posterolateral site, then tended to level off. The reduction of strength was most pronounced in the centre of the condyles. The penetration tests were good predictors of the static compressive strength of the proximal tibia. Correlation coefficients of approximately 0.90 were obtained indicating statistically highly significant correlations (p less than or equal to 0.00001). The tests were carried out with equipment developed for in vivo measurements of cancellous bone strength during total knee replacement. The findings confirm the close relationship of these investigations to conventional compression tests.

Entities:  

Mesh:

Year:  1986        PMID: 3804529     DOI: 10.1007/bf00454408

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  16 in total

1.  Hardness of the subchondral bone of the tibial condyles in the normal state and in osteoarthritis and rheumatoid arthritis.

Authors:  P Lereim; I Goldie; E Dahlberg
Journal:  Acta Orthop Scand       Date:  1974

2.  Variations in strength and structure of cancellous bone at the knee.

Authors:  J C Behrens; P S Walker; H Shoji
Journal:  J Biomech       Date:  1974-05       Impact factor: 2.712

3.  The load-bearing area in the knee joint.

Authors:  P S Walker; J V Hajek
Journal:  J Biomech       Date:  1972-11       Impact factor: 2.712

4.  The mechanics of the knee joint in relation to normal walking.

Authors:  J B Morrison
Journal:  J Biomech       Date:  1970-01       Impact factor: 2.712

5.  Compressive strength of tibial cancellous bone. Instron and osteopenetrometer measurements in an autopsy material.

Authors:  I Hvid; P Christensen; J Søondergaard; P B Christensen; C G Larsen
Journal:  Acta Orthop Scand       Date:  1983-12

6.  Cancellous bone strength measurements with the osteopenetrometer.

Authors:  I Hvid; K Andersen; S Olesen
Journal:  Eng Med       Date:  1984-04

7.  Cancellous bone strength at the proximal human tibia.

Authors:  I Hvid; J Jensen
Journal:  Eng Med       Date:  1984-01

8.  Mechanical tests on the tibial components of non-hinged knee prostheses.

Authors:  J H Bargren; W H Day; M A Freeman; S A Swanson
Journal:  J Bone Joint Surg Br       Date:  1978-05

9.  Gait analysis with an angle diagram technique: application in healthy persons and in studies of Marmor knee arthroplasties.

Authors:  K Kolstad; A Wigren; K Oberg
Journal:  Acta Orthop Scand       Date:  1982-10

10.  The contact area and pressure distribution pattern of the knee. A study of normal and osteoarthrotic knee joints.

Authors:  T Fukubayashi; H Kurosawa
Journal:  Acta Orthop Scand       Date:  1980-12
View more
  1 in total

1.  Quantitative morphology of the subchondral plate of the tibial plateau.

Authors:  S Milz; R Putz
Journal:  J Anat       Date:  1994-08       Impact factor: 2.610

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.