Literature DB >> 7334864

Characteristic impedance of the proximal aorta determined in the time and frequency domain: a comparison.

J P Dujardin, D N Stone.   

Abstract

Mesh:

Year:  1981        PMID: 7334864     DOI: 10.1007/bf02442770

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  9 in total

1.  Effects of alterations in aortic input impedance on the force-velocity-length relationship in the intact canine heart.

Authors:  H Pouleur; J W Covell; J Ross
Journal:  Circ Res       Date:  1979-07       Impact factor: 17.367

2.  Influence of central and peripheral changes on the hydraulic input impedance of the systemic arterial tree.

Authors:  N Westerhof; G Elzinga; G C van den Bos
Journal:  Med Biol Eng       Date:  1973-11

3.  Dynamic pressure-flow diagrams and impedance in experimental arterial stenosis and in stenotic atherosclerosis.

Authors:  D J Farrar; G S Malindzak; G Johnson
Journal:  Ann Biomed Eng       Date:  1978-12       Impact factor: 3.934

4.  Aortic input impedance and left ventricular energetics in acute isovolumic anaemia.

Authors:  T N Clarke; C Prys-Roberts; G Biro; P Foëx; M J Bennett
Journal:  Cardiovasc Res       Date:  1978-01       Impact factor: 10.787

5.  Response of systemic arterial input impedance to volume expansion and hemorrhage.

Authors:  J P Dujardin; D N Stone; L T Paul; H P Pieper
Journal:  Am J Physiol       Date:  1980-06

6.  Fourier analysis of left ventricular performance. Evaluation of impedance matching.

Authors:  F L Abel
Journal:  Circ Res       Date:  1971-02       Impact factor: 17.367

7.  Input impedance of the systemic circulation.

Authors:  M F O'Rourke; M G Taylor
Journal:  Circ Res       Date:  1967-04       Impact factor: 17.367

8.  Baroreceptor reflex control of arterial hemodynamics in the dog.

Authors:  R H Cox; R J Bagshaw
Journal:  Circ Res       Date:  1975-12       Impact factor: 17.367

9.  Aortic input impedance during nitroprusside infusion. A reconsideration of afterload reduction and beneficial action.

Authors:  C J Pepine; W W Nichols; R C Curry; C R Conti
Journal:  J Clin Invest       Date:  1979-08       Impact factor: 14.808

  9 in total
  17 in total

1.  Analytical relationship between arterial input impedance and the three-element Windkessel series resistance.

Authors:  G Gnudi
Journal:  Med Biol Eng Comput       Date:  1998-07       Impact factor: 2.602

2.  Arterial stiffness, pressure and flow pulsatility and brain structure and function: the Age, Gene/Environment Susceptibility--Reykjavik study.

Authors:  Gary F Mitchell; Mark A van Buchem; Sigurdur Sigurdsson; John D Gotal; Maria K Jonsdottir; Ólafur Kjartansson; Melissa Garcia; Thor Aspelund; Tamara B Harris; Vilmundur Gudnason; Lenore J Launer
Journal:  Brain       Date:  2011-11       Impact factor: 13.501

3.  Estimation of arterial compliance in aortic regurgitation: three methods evaluated in pigs.

Authors:  S A Slørdahl; H Piene; J E Solbakken; O Rossvoll; S O Samstad; B A Angelsen
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

4.  Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop.

Authors:  A W Khir; M J P Swalen; J Feng; K H Parker
Journal:  Med Biol Eng Comput       Date:  2007-08-21       Impact factor: 2.602

5.  Hemodynamic and Mechanical Properties of the Proximal Aorta in Young and Middle-Aged Adults With Isolated Systolic Hypertension: The Dallas Heart Study.

Authors:  Yuichiro Yano; Ian J Neeland; Colby Ayers; Ronald Peshock; Jarett D Berry; Donald M Lloyd-Jones; Philip Greenland; Gary F Mitchell; Wanpen Vongpatanasin
Journal:  Hypertension       Date:  2017-05-15       Impact factor: 10.190

6.  Characteristic impedance: frequency or time domain approach?

Authors:  M Umar Qureshi; Mitchel J Colebank; David A Schreier; Diana M Tabima; Mansoor A Haider; Naomi C Chesler; Mette S Olufsen
Journal:  Physiol Meas       Date:  2018-01-31       Impact factor: 2.833

7.  Identification of the three-element windkessel model incorporating a pressure-dependent compliance.

Authors:  A Cappello; G Gnudi; C Lamberti
Journal:  Ann Biomed Eng       Date:  1995 Mar-Apr       Impact factor: 3.934

8.  Arterial windkessel parameter estimation: a new time-domain method.

Authors:  Y Shim; A Pasipoularides; C A Straley; T G Hampton; P F Soto; C H Owen; J W Davis; D D Glower
Journal:  Ann Biomed Eng       Date:  1994 Jan-Feb       Impact factor: 3.934

9.  Pressure dependence of the canine aortic characteristic impedance and the effects of alterations in smooth muscle activity.

Authors:  D N Stone; J P Dujardin
Journal:  Med Biol Eng Comput       Date:  1985-07       Impact factor: 2.602

10.  Validity of the Water Hammer Formula for Determining Regional Aortic Pulse Wave Velocity: Comparison of One-Point and Two-Point (Foot-to-Foot) Measurements Using a Multisensor Catheter in Human.

Authors:  Shizuo Hanya
Journal:  Ann Vasc Dis       Date:  2013-05-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.