Literature DB >> 7320296

Identification of the optimal orientation of oblique sections through multiple parallel CT images.

L D Harris.   

Abstract

A method for identifying the optimal orientation of images of oblique sections computed from a "stack" of parallel computed tomography (CT) scans is presented. The identification of the optimal orientation is facilitated by the display of the stack of cross-sectional images (volume image) in three dimensions. Moreover, by displaying the section image as a brightened plane within the volume, imaged anatomic landmarks may be utilized to guide the process of identifying the desired image plane orientation. The volume image display method, termed projection imaging, involves the numerical projection of the volume picture elements (voxels) of the three-dimensional (3-D) reconstruction onto a plane to form a two-dimensional projection image. For X-ray CT, these projections are analagous to, and appear very much like, conventional radiographs. The volume image is seen in three dimensions by appropriately viewing stereo-pair projections of the volume formed from viewpoints that are 2 to 8 degrees apart. The display of the 3-D reconstruction as a volume image eliminates the need for the observer to mentally reconstruct the spatial relationships of the oblique section to anatomic features within the volume.

Mesh:

Year:  1981        PMID: 7320296     DOI: 10.1097/00004728-198112000-00018

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

1.  A system for interactive volume analysis (SIVA) of 4-D biomedical images.

Authors:  J J Camp; M C Stacy; R A Robb
Journal:  J Med Syst       Date:  1987-08       Impact factor: 4.460

2.  Renal cortical perfusion--preliminary experience with the dynamic spatial reconstructor (DSR).

Authors:  T Iwasaki; E L Ritman; M J Fiksen-Olsen; J C Romero; F G Knox
Journal:  Ann Biomed Eng       Date:  1985       Impact factor: 3.934

Review 3.  Origins of and lessons from quantitative functional X-ray computed tomography of the lung.

Authors:  Eric A Hoffman
Journal:  Br J Radiol       Date:  2022-03-01       Impact factor: 3.629

4.  The Dynamic Spatial Reconstructor: investigating congenital heart disease in four dimensions.

Authors:  L J Sinak; E A Hoffman; P R Julsrud; D D Mair; J B Seward; D J Hagler; L D Harris; R A Robb; E L Ritman
Journal:  Cardiovasc Intervent Radiol       Date:  1984       Impact factor: 2.740

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.