Literature DB >> 4037455

Renal cortical perfusion--preliminary experience with the dynamic spatial reconstructor (DSR).

T Iwasaki, E L Ritman, M J Fiksen-Olsen, J C Romero, F G Knox.   

Abstract

The three-dimensional image data generated by the Dynamic Spatial Reconstructor (DSR) enables measurement of the three-dimensional distribution of blood supply in organs. We have applied this imaging technique to evaluate renal cortical blood flow distribution and compare it with distribution of radiolabeled microspheres. The DSR, a high temporal resolution volumetric roentgenographic computed tomographic scanner, was used to scan the volume containing a kidney in 0.13-0.26 s and repeating this scan 8-4 times per s for six s during a renal arteriogram. Five anesthetized dogs were studied in the prone position with the left kidney exteriorized through a flank incision. An electromagnetic flowmeter was placed around the renal artery and a needle placed retrograde into the artery for injection of a 2 cc bolus of contrast agent. During the scan the contrast agent was injected over a four s period during which radioactively labelled microspheres were injected into the left atrium. The tomographic images of approximately 10 parallel, 5 mm thick sagittal slices corresponding to the slices of the kidney used for counting microspheres in the cortical layers were displayed and analyzed. The time point chosen for analysis was the one in which peak brightness (i.e., concentration of contrast agent) was detected in the cortex. The spatial distribution of peak brightness values was compared to the number of microspheres at the same sampling locations. The microsphere-based value of regional cortical blood flow fell below the regression line for the juxtamedullary cortex and above for the outer cortex. This result is consistent with the preferential distribution of microspheres to the outer cortex whereas the contrast agent distributed more uniformly throughout the cortex.

Entities:  

Mesh:

Year:  1985        PMID: 4037455     DOI: 10.1007/bf02584243

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  18 in total

1.  Accurate measurement of liver, kidney, and spleen volume and mass by computerized axial tomography.

Authors:  S B Heymsfield; T Fulenwider; B Nordlinger; R Barlow; P Sones; M Kutner
Journal:  Ann Intern Med       Date:  1979-02       Impact factor: 25.391

2.  Pressure-dependent heterogeneity of renal cortical blood flow in dogs.

Authors:  J L McNay; Y Abe
Journal:  Circ Res       Date:  1970-10       Impact factor: 17.367

3.  Cortical volume of the normal human kidney. Correlated angiographic and morphologic investigations.

Authors:  V Hegedüs; P Faarup
Journal:  Acta Radiol Diagn (Stockh)       Date:  1972-07

4.  Excretion urography. I. Factors determining the excretion of Hypaque.

Authors:  W R Cattell; I K Fry; A G Spencer; P Purkiss
Journal:  Br J Radiol       Date:  1967-08       Impact factor: 3.039

5.  Renal transport of diatrizoate in the rabbit, dog, and rat.

Authors:  G H Mudge; W O Berndt; A Saunders; B Beattie
Journal:  Nephron       Date:  1971       Impact factor: 2.847

6.  The DSR -- a high temporal resolution volumetric roentgenographic CT scanner.

Authors:  J H Kinsey; R A Robb; E L Ritman; E H Wood
Journal:  Herz       Date:  1980-06       Impact factor: 1.443

7.  Computed tomography in the evaluation of the solitary or unilateral nonfunctioning kidney.

Authors:  W S Forbes; I Isherwood; R A Fawcitt
Journal:  J Comput Assist Tomogr       Date:  1978-09       Impact factor: 1.826

8.  Identification of the optimal orientation of oblique sections through multiple parallel CT images.

Authors:  L D Harris
Journal:  J Comput Assist Tomogr       Date:  1981-12       Impact factor: 1.826

9.  A preliminary investigation of the role of dynamic computed tomography in renovascular hypertension.

Authors:  E R Heinz; P J Dubois; B P Drayer; R Hill
Journal:  J Comput Assist Tomogr       Date:  1980-02       Impact factor: 1.826

10.  Noninvasive quantitative imaging of shape and volume of lungs.

Authors:  E A Hoffman; L J Sinak; R A Robb; E L Ritman
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.