Literature DB >> 7309769

The influence of implant elastic modulus on the stress distribution around LTI carbon and aluminum oxide dental implants.

S D Cook, J J Klawitter, A M Weinstein.   

Abstract

A three-dimensional finite element analysis (FEA) has been used to determine the effect of implant elastic modulus on stresses in tissues around LTI carbon and aluminum oxide dental implants. The finite element model was constructed to represent a baboon mandible containing a blade type dental implant. A three unit fixed bridge was modeled connecting the dental implant to a natural molar. The results of the study indicate that stress levels of approximately a factor of 3 lower in the crestal region can be expected for aluminum oxide implants when compared to the LTI carbon implants. It was also observed that the use of LTI carbon and aluminum oxide dental implants as an abutment in a fixed bridge results in a reduction of stresses in tissues around the natural tooth when compared to normal physiological stress levels.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7309769     DOI: 10.1002/jbm.820150612

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  9 in total

1.  Pyrocarbon interposition shoulder arthroplasty in advanced collapse of the humeral head.

Authors:  R Hudek; B Werner; A F Abdelkawi; F Gohlke
Journal:  Orthopade       Date:  2017-12       Impact factor: 1.087

2.  Radiographic interpretation of carpometacarpal arthroplasty: correlation between radiographic loosening and clinical outcome.

Authors:  Laurence Stillwater; Brett Memauri; Imran Ratanshi; Avinash Islur; Thelina Amaratunga
Journal:  Skeletal Radiol       Date:  2017-04-19       Impact factor: 2.199

3.  Early outcomes of arthroplasty of the first carpometacarpal joint using pyrocarbon spherical implants.

Authors:  Omar Bengezi; Anthony Vo
Journal:  Plast Surg (Oakv)       Date:  2014       Impact factor: 0.947

4.  Pyrolytic carbon endoprosthetic replacement for osteonecrosis and femoral fracture of the hip: a pilot study.

Authors:  Thomas L Bernasek; Jennifer L Stahl; Derek Pupello
Journal:  Clin Orthop Relat Res       Date:  2009-04-11       Impact factor: 4.176

5.  [Research progress in artificial metacarpophalangeal joint and interphalangeal joint prostheses].

Authors:  Ling Yao; Chuan Li; Jun Li
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-10-15

6.  Surface replacement arthroplasty of the proximal interphalangeal and metacarpophalangeal joints: The current state.

Authors:  Harvinder Singh; Joseph J Dias
Journal:  Indian J Plast Surg       Date:  2011-05

7.  Chitosan/hydroxyapatite composite coatings on porous Ti6Al4V titanium implants: in vitro and in vivo studies.

Authors:  Ting Zhang; Xinwei Zhang; Mengyun Mao; Jiayi Li; Ting Wei; Huiqiang Sun
Journal:  J Periodontal Implant Sci       Date:  2020-12       Impact factor: 2.614

8.  Mechanobiologically optimized Ti-35Nb-2Ta-3Zr improves load transduction and enhances bone remodeling in tilted dental implant therapy.

Authors:  Chuanyuan Mao; Weijun Yu; Min Jin; Yingchen Wang; Xiaoqing Shang; Lu Lin; Xiaoqin Zeng; Liqiang Wang; Eryi Lu
Journal:  Bioact Mater       Date:  2022-03-16

Review 9.  Parameters Influencing the Outcome of Additive Manufacturing of Tiny Medical Devices Based on PEEK.

Authors:  Yiqiao Wang; Wolf-Dieter Müller; Adam Rumjahn; Andreas Schwitalla
Journal:  Materials (Basel)       Date:  2020-01-18       Impact factor: 3.623

  9 in total