Literature DB >> 7296793

Ultrasonic duplex scanning for disease of the carotid artery.

G Fell, D J Phillips, P M Chikos, J D Harley, B L Thiele, D E Strandness.   

Abstract

The duplex ultrasonic scanner combines real-time B-mode imaging with a single-gate, variable-range pulsed Doppler. The detection and categorization of the severity of carotid artery atherosclerosis is achieved by performing spectral analysis of the pulsed Doppler velocity signal obtained from vessels of interest. Using this technique, 750 patients with suspected extracranial carotid artery disease were evaluated between January 1978 and January 1980. One hundred thirty-five of these 750 patients (18%) underwent cerebral arteriography performed with biplanar views of the carotid bifurcation. The degree of stenosis was measured independently in these patients and was available for comparison with the results of duplex scanning and spectral analysis. Duplex scanning correctly detected the presence of disease in 252 of 259 carotid arteries studied (97%). The extent of involvement varied from plaques that produced less than 10% diameter reduction to those that resulted in a total occlusion. The technique was less accurate with lesions that produced less than 10% diameter reduction.

Entities:  

Mesh:

Year:  1981        PMID: 7296793     DOI: 10.1161/01.cir.64.6.1191

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  11 in total

1.  Christian Doppler and the influence of his work on modern medicine.

Authors:  Franz Kainberger; Sepp Leodolter
Journal:  Wien Klin Wochenschr       Date:  2004-02-28       Impact factor: 1.704

2.  Sonographic NASCET index: a new doppler parameter for assessment of internal carotid artery stenosis.

Authors:  Gasser M Hathout; James R Fink; Suzie M El-Saden; Edward G Grant
Journal:  AJNR Am J Neuroradiol       Date:  2005-01       Impact factor: 3.825

3.  The limitations of diagnosis of carotid occlusion by Doppler ultrasound.

Authors:  N M Bornstein; Z G Beloev; J W Norris
Journal:  Ann Surg       Date:  1988-03       Impact factor: 12.969

4.  Continuous-wave versus range-gated pulsed Doppler power frequency spectrum analysis in the detection of carotid arterial occlusive disease.

Authors:  T R Harward; E F Bernstein; A Fronek
Journal:  Ann Surg       Date:  1986-07       Impact factor: 12.969

5.  Pulsed Doppler sonography as an aid in ultrasound-guided aspiration biopsy.

Authors:  J P McGahan; M W Anderson
Journal:  Gastrointest Radiol       Date:  1987

6.  Detection of carotid occlusive disease by pulsed Doppler spectral analysis.

Authors:  D Russell; K F Lindegaard; P Nakstad; R Nyberg-Hansen; K G Oygarden
Journal:  J Neurol Neurosurg Psychiatry       Date:  1984-12       Impact factor: 10.154

Review 7.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11

8.  Doppler ultrasound in the diagnosis of intestinal ischemia.

Authors:  G G Hartnell; R N Gibson
Journal:  Gastrointest Radiol       Date:  1987

9.  Accuracy of contrast-enhanced MR angiography in predicting angiographic stenosis of the internal carotid artery: linear regression analysis.

Authors:  Gasser M Hathout; Michael J Duh; Suzie M El-Saden
Journal:  AJNR Am J Neuroradiol       Date:  2003-10       Impact factor: 3.825

10.  Noninvasive assessment of carotid artery disease.

Authors:  D F Bandyk; B L Thiele
Journal:  West J Med       Date:  1983-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.