Literature DB >> 6392482

Detection of carotid occlusive disease by pulsed Doppler spectral analysis.

D Russell, K F Lindegaard, P Nakstad, R Nyberg-Hansen, K G Oygarden.   

Abstract

In this study a new pulsed Doppler spectral analysis system was used for the evaluation of extracranial carotid disease. When compared to the arteriography findings in 224 carotid arteries, the Doppler examination correctly detected all stenoses greater than 25%, all occlusions, all normal vessels, and 43% of stenosis causing a diameter reduction of less than 25%.

Entities:  

Mesh:

Year:  1984        PMID: 6392482      PMCID: PMC1028138          DOI: 10.1136/jnnp.47.12.1307

Source DB:  PubMed          Journal:  J Neurol Neurosurg Psychiatry        ISSN: 0022-3050            Impact factor:   10.154


  12 in total

1.  Pulsed Doppler ultrasound detection of flow disturbances in arteriosclerosis.

Authors:  R W Felix; B Sigel; R J Gibson; J Williams; G L Popky; A L Edelstein; J R Justin
Journal:  J Clin Ultrasound       Date:  1976-08       Impact factor: 0.910

2.  Digital subtraction angiography and continuous-wave Doppler studies. Their use in postoperative study of patients with carotid endarterectomy.

Authors:  C W Acher; W D Turnipseed; J F Sackett; C M Strother; A Crummy; C Mistretta
Journal:  Arch Surg       Date:  1983-04

3.  Cerebrovascular assessment using a Doppler carotid scanner and real-time frequency analysis.

Authors:  K W Johnston; D deMorais; M Kassam; P M Brown
Journal:  J Clin Ultrasound       Date:  1981-10       Impact factor: 0.910

Review 4.  Cervical arteriosclerosis--diagnostic advances in need of a clinical answer.

Authors:  C M Strother; A B Crummy
Journal:  Stroke       Date:  1982 Sep-Oct       Impact factor: 7.914

5.  Carotid artery velocity patterns in normal and stenotic vessels.

Authors:  W M Blackshear; D J Phillips; P M Chikos; J D Harley; B L Thiele; D E Strandness
Journal:  Stroke       Date:  1980 Jan-Feb       Impact factor: 7.914

6.  Ultrasonic duplex scanning for disease of the carotid artery.

Authors:  G Fell; D J Phillips; P M Chikos; J D Harley; B L Thiele; D E Strandness
Journal:  Circulation       Date:  1981-12       Impact factor: 29.690

7.  Comparison of pulsed Doppler and real-time B-mode echo arteriography for noninvasive imaging of the extracranial carotid arteries.

Authors:  R W Hobson; S M Berry; A S Katocs; J A O'Donnell; Z Jamil; J P Savitsky
Journal:  Surgery       Date:  1980-03       Impact factor: 3.982

8.  Problems of carotid Doppler scanning which can be overcome by using frequency analysis.

Authors:  K W Johnston; P M Brown; M Kassam
Journal:  Stroke       Date:  1982 Sep-Oct       Impact factor: 7.914

9.  Local Doppler audio spectra in normal and stenosed carotid arteries in man.

Authors:  R S Reneman; M P Spencer
Journal:  Ultrasound Med Biol       Date:  1979       Impact factor: 2.998

10.  Detection of carotid occlusive disease by ultrasonic imaging and pulsed Doppler spectrum analysis.

Authors:  W M Blackshear; D J Phillips; B L Thiele; J H Hirsch; P M Chikos; M R Marinelli; K J Ward; D E Strandness
Journal:  Surgery       Date:  1979-11       Impact factor: 3.982

View more
  3 in total

1.  Regional cerebral blood flow (rCBF) and cerebral vasoreactivity in patients with retinal ischaemic symptoms.

Authors:  E Kerty; D Russell; S J Bakke; R Nyberg-Hansen; K Rootwell
Journal:  J Neurol Neurosurg Psychiatry       Date:  1989-12       Impact factor: 10.154

2.  Patency and flow velocity profiles in the internal carotid artery assessed by digital subtraction angiography and Doppler studies three months following endarterectomy.

Authors:  D Russell; S J Bakke; J Wiberg; P Nakstad; R Nyberg-Hansen
Journal:  J Neurol Neurosurg Psychiatry       Date:  1986-02       Impact factor: 10.154

3.  Doppler diagnosis of intracranial artery occlusive disorders.

Authors:  K F Lindegaard; S J Bakke; R Aaslid; H Nornes
Journal:  J Neurol Neurosurg Psychiatry       Date:  1986-05       Impact factor: 10.154

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.