Literature DB >> 7294987

Glass-ceramic coated implants. A simple model for a loaded hip prosthesis with a bioactive interface.

G A Fuchs, K Deutscher.   

Abstract

The favorable histological results at the bone-implant-interface of glass ceramic material are well-known. The mechanical properties of the solid material limit it's application for implants. Therefore metallic hip implants had been coated by glass ceramic granules, by a special technique, to transfer the bioactive property of the glass ceramic on to the metal stem. The following loaded experiments in rabbits with a simple model of a hip endoprosthesis showed a direct and tight bonding between implant surface and surrounding new bone formation. These findings demonstrate a possibility to anchor a joint endoprosthesis without the use of bone cement.

Entities:  

Mesh:

Year:  1981        PMID: 7294987     DOI: 10.1007/bf00460799

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  8 in total

1.  [Bioactive glass ceramics as an implantation material in dental surgery].

Authors:  V Strunz; M Bunte; R Stellmach; U M Gross; K Kühl; H Brömer; U K Deutscher
Journal:  Dtsch Zahnarztl Z       Date:  1977-04

2.  [Fixing endoprostheses without cement using the principle of "weightbearing ribbing" (author's transl)].

Authors:  H Mittelmeier
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-02

3.  Compatibility and long-term stability of glass-ceramic implants.

Authors:  B A Blenckè
Journal:  J Biomed Mater Res       Date:  1978-05

4.  A noncemented total hip prosthesis.

Authors:  R Judet; M Siguier; B Brumpt; T Judet
Journal:  Clin Orthop Relat Res       Date:  1978 Nov-Dec       Impact factor: 4.176

5.  [Comparative experimental investigations with bioglass (L. L. Hench), Al2O3-ceramic and Al2O3-ceramic coated with a mod. Bioglass. I. Results of experiments under non-loaded conditions (author's transl)].

Authors:  P Griss; E Werner; G Heimke; R Buchinger
Journal:  Arch Orthop Unfallchir       Date:  1977-11-21

6.  Short term bonding behaviour of bioglass coatings on metal substrate.

Authors:  P Ducheyne; L L Hench; A Kagan; M Martens; J C Mulier
Journal:  Arch Orthop Trauma Surg       Date:  1979-08

7.  Investigations with bioactivated polymethylmethacrylates.

Authors:  W Hennig; B A Blencke; H Brömer; K K Deutscher; A Gross; W Ege
Journal:  J Biomed Mater Res       Date:  1979-01

8.  The anchoring of glass ceramics of different solubility in the femur of the rat.

Authors:  U M Gross; V Strunz
Journal:  J Biomed Mater Res       Date:  1980-09
  8 in total
  1 in total

1.  Glass-ceramic metal composite bone fixation: effect of surface parameters.

Authors:  R U Repo; H Shimizu; J Occhionorelli; S Margolian
Journal:  Arch Orthop Trauma Surg       Date:  1985
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.