Literature DB >> 496586

Short term bonding behaviour of bioglass coatings on metal substrate.

P Ducheyne, L L Hench, A Kagan, M Martens, J C Mulier.   

Abstract

Bioglass specimens were implanted in 11 dogs for periods ranging between two and twelve weeks in order to study the short term bonding behaviour of bioglass coated on metal. Metal fibre porous coated specimens without bone growth inducive microlayer were implanted as controls. The conclusions reached pertain to the validity of push out test results, bioglass short term bonding and the effect of the dipping procedure to coat bioglass on metal: 1. It is impossible to compare the bonding effectiveness of bonding materials tested under slightly differing circumstances, and a fortiori at different laboratories, 2. there is no sufficient evidence to establish a difference in bone bonding strength with regard to trabecular bone of bioglass and metal fibre porous coated specimens at 2 and 4 weeks; at 12 weeks, however, a higher interfacial failure shear strength is obtained with the control porous specimens, 3. bone bonding may be hampered by compositional differences arising as a result of the processing of a bioglass on metal coating. Technologically it is, however, possible to exclude this problem.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 496586     DOI: 10.1007/bf00618439

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  15 in total

1.  The influence of surface chemistry on implant interface histology: a theoretical basis for implant materials selection.

Authors:  A E Clark; L L Hench; H A Paschall
Journal:  J Biomed Mater Res       Date:  1976-03

2.  Fiber metal composites in the fixation of skeletal prosthesis.

Authors:  J Galante; W Rostoker
Journal:  J Biomed Mater Res       Date:  1973

3.  Biomechanical properties of paired canine fibulas.

Authors:  J J Puhl; G Piotrowski; W F Enneking
Journal:  J Biomech       Date:  1972-07       Impact factor: 2.712

4.  The safety of acrylic bone cement.

Authors:  D J Dandy
Journal:  Injury       Date:  1973-11       Impact factor: 2.586

5.  Skeletal fixation with self-curing polymethyl methacrylate. A report of 23 canine total hip replacements.

Authors:  H C Amstutz; L Lurie; P Bullough
Journal:  Clin Orthop Relat Res       Date:  1972-05       Impact factor: 4.176

6.  Failure of total knee arthroplasty due to loosening and deformation of the tibial component.

Authors:  P Ducheyne; A Kagan; J A Lacey
Journal:  J Bone Joint Surg Am       Date:  1978-04       Impact factor: 5.284

7.  A high-modulus polymer for porous orthopedic implants: biomechanical compatibility of porous implants.

Authors:  M Spector; M J Michno; W H Smarook; G T Kwiatkowski
Journal:  J Biomed Mater Res       Date:  1978-09

8.  Influence of a functional dynamic loading on bone ingrowth into surface pores of orthopedic implants.

Authors:  P Ducheyne; P De Meester; E Aernoudt
Journal:  J Biomed Mater Res       Date:  1977-11

9.  Tissue, cellular and subcellular events at a bone-ceramic hydroxylapatite interface.

Authors:  M Jarcho; J F Kay; K I Gumaer; R H Doremus; H P Drobeck
Journal:  J Bioeng       Date:  1977-01

10.  Effect of hydroxyapatite impregnation on skeletal bonding of porous coated implants.

Authors:  P Ducheyne; L L Hench; A Kagan; M Martens; A Bursens; J C Mulier
Journal:  J Biomed Mater Res       Date:  1980-05
View more
  3 in total

1.  Effect of glass bioactivity on new bone development induced by demineralized bone matrix in a rat extraskeletal site.

Authors:  K J Pajamäki; O H Andersson; T S Lindholm; K H Karlsson; A Yli-Urpo; P Laippala; R P Happonen
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

2.  Glass-ceramic coated implants. A simple model for a loaded hip prosthesis with a bioactive interface.

Authors:  G A Fuchs; K Deutscher
Journal:  Arch Orthop Trauma Surg       Date:  1981

3.  Skeletal fixation of implants by bone ingrowth into surface pores.

Authors:  M Martens; P Ducheyne; P De Meester; J C Mulier
Journal:  Arch Orthop Trauma Surg       Date:  1980
  3 in total