Literature DB >> 7290912

Averaging, selective averaging and latency-corrected averaging.

J Peregrin, M Valach.   

Abstract

Although latency-corrected averaging and selective averaging represent frequency used alternatives to the time-locked averaging, little is known about the changes of the signal-to-noise ratio (SNR) associated with their application. For this reason, visual evoked responses (VERs) to blank and checkerboard patterned flashes of light (5.6 cd/m2) were recorded in 15 subjects using a referential (Oz - A1 + 2) and a bipolar (Oz - Pz) derivation, and interstimulus intervals (ISI) of 1.4s and 2.4s; SNRs were calculated for all combinations. With time-locked averaging (referential derivation) the mean SNR of single VERs was 0.35 to blank stimuli and 0.68 to patterned stimuli. With latency-corrected averaging, the means SNR rose to 0.56 (0.74), and with selective averaging it increased to 0.81 (1.00). A combined procedure of selective and latency-corrected averaging yielded the highest mean SNR values of single VERs: 0.98 (1.21). Increasing ISIs from 1.4 - 2.4s did not change the results; the mean SNR values were always higher in bipolar than in referential derivations. The selective, latency-corrected averaging produced higher SNRs, and the group mean number of detectable single VERs (62% of the single VERs to blank stimuli, and 74% of the single VERs to patterned stimuli) and the latency variability of the single VERs: -0.33 +/- 14.5 ms (blank stimulation) and -0.48 +/- 13.96 ms (patterned stimulation).

Mesh:

Year:  1981        PMID: 7290912     DOI: 10.1007/bf00657007

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  8 in total

1.  [The estimation of single cortical evoked responses in the EEG by computer].

Authors:  G Pfurtscheller
Journal:  Methods Inf Med       Date:  1972-04       Impact factor: 2.176

2.  Use of an adaptive filter to characterize signal-noise relationships.

Authors:  E K Harris; C D Woody
Journal:  Comput Biomed Res       Date:  1969-02

3.  Visual evoked responses to the upper and lower half-field stimulation in a dark-adapted man.

Authors:  J Peregrin; I Pastrnáková; A Pastrnák
Journal:  Pflugers Arch       Date:  1978-08-25       Impact factor: 3.657

4.  [Correlation analysis of averaged and unaveraged evoked potentials].

Authors:  E David; P Finkenzeller; S Kallert; W D Keidel
Journal:  Kybernetik       Date:  1971-07

5.  Comparison of different techniques for processing evoked potentials.

Authors:  J I Aunon; R W Sencaj
Journal:  Med Biol Eng Comput       Date:  1978-11       Impact factor: 2.602

6.  Statistical detection of individual evoked responses: an evaluation of Woody's adaptive filter.

Authors:  D G Wastell
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1977-06

7.  Selective averaging of the intracerebral click evoked responses in man: an improved method of measuring latencies and amplitudes.

Authors:  G Pfurtscheller; R Cooper
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1975-02

8.  Signal to noise ratio and response variability measurements in single trial evoked potentials.

Authors:  R Coppola; R Tabor; M S Buchsbaum
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1978-02
  8 in total
  2 in total

1.  Role of latency jittering correction in motion-onset VEP amplitude decay during prolonged visual stimulation.

Authors:  J Kremláček; M Hulan; M Kuba; Z Kubová; J Langrová; F Vít; J Szanyi
Journal:  Doc Ophthalmol       Date:  2012-03-20       Impact factor: 2.379

2.  Results of modelling and physiological examination of movement-related heart-rate reactions in neonates.

Authors:  H Witte; F Liese; S Glaser; D Hoyer
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.