Literature DB >> 7276018

Fretting corrosion in saline and serum.

S A Brown, K Merritt.   

Abstract

Fretting corrosion of stainless-steel round hole plates and spherical head screws was studied using a simulator that produced a rocking motion of the heads in the plate holes. Experiments were run for 7 days, with the simulator producing 1 oscillation/s for 16 h/day. Fretting corrosion was studied in 0.9% NaCl and in a 10% solution of fetal calf serum in saline. The results showed a tenfold decrease in fretting corrosion when the serum was added to the saline. Measurements of the weight of the two screws and two-hole plate showed those in saline lost 2.9 mg as compared to 0.3 for those in 10% serum. The concentration of nickel in the saline solutions was 12.4 micrograms/mL compared with 0.85 in serum. Visual examination of the solutions and implants revealed that those in saline had a significant amount of corrosion products while those tested in 10% serum were bright and shiny. Recordings of electrical potentials demonstrated that the addition of serum to saline significantly reduced the change in potential from rest to fretting condition.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7276018     DOI: 10.1002/jbm.820150404

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  8 in total

1.  Characterizing fretting damage in different test media for cardiovascular device durability testing.

Authors:  J D Weaver; L Ramirez; S Sivan; M Di Prima
Journal:  J Mech Behav Biomed Mater       Date:  2018-04-04

Review 2.  Corrosion of Metallic Biomaterials: A Review.

Authors:  Noam Eliaz
Journal:  Materials (Basel)       Date:  2019-01-28       Impact factor: 3.623

3.  Effect of fluoride agents on surface characteristics of NiTi wires. An ex vivo investigation.

Authors:  Prasad Chitra; G S Prashantha; Arun Rao
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-05

4.  Fretting-corrosion in Hip Implant Modular Junctions: New Experimental Set-up and Initial Outcome.

Authors:  D Royhman; M Patel; M J Runa; J J Jacobs; N J Hallab; M A Wimmer; M T Mathew
Journal:  Tribol Int       Date:  2015-11-01       Impact factor: 4.872

5.  The corrosion resistance of composite arch wire laser-welded by NiTi shape memory alloy and stainless steel wires with Cu interlayer in artificial saliva with protein.

Authors:  Chao Zhang; Xinhua Sun; Xu Hou; Hongmei Li; Daqian Sun
Journal:  Int J Med Sci       Date:  2013-06-21       Impact factor: 3.738

6.  In vitro assessment of serum-saline ratios for fluid simulator testing of highly modular spinal implants with articulating surfaces.

Authors:  Nadim Hallab; Ashutosh Khandha; George Malcolmson; J P Timm
Journal:  SAS J       Date:  2008-12-01

7.  In vitro testing for hip head-neck taper tribocorrosion: A review of experimental methods.

Authors:  Christian M Wight; Emil H Schemitsch
Journal:  Proc Inst Mech Eng H       Date:  2022-02-10       Impact factor: 1.617

Review 8.  Tissue response to titanium implant using scanning electron microscope.

Authors:  Vijay P Nautiyal; Ankur Mittal; Amit Agarwal; Anupam Pandey
Journal:  Natl J Maxillofac Surg       Date:  2013-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.