Literature DB >> 7259461

Five years experience with ceramic-metal-composite hip endoprostheses. I. clinical evaluation.

P Griss, G Heimke.   

Abstract

Clinical experience with 130 endoprostheses, entirely made of ceramic, having an average 5 year follow-up is reported. Excellent to sufficient results were seen in 84% of all cases. A number of particular matters of interest (operative technique, radiological morphology of the bone/ceramic bone interface etc.) are discussed in detail. Complications (loosening of components: 2%; component fracture: 6%, wear phenomena etc.) are described and documented including histological observations from capsular tissue of total ceramic hip joints. The whole system has basically stood the test, during the implantation period, modifications to improve the function of the system will be described in another publication.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7259461     DOI: 10.1007/bf00632972

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  12 in total

1.  [The alumina oxide ceramic-metal composite endoprosthesis. A new hip endoprosthesis for partially cement free implantation (author's transl)].

Authors:  P Griss; G Heimke; H F von Andrian-Werburg
Journal:  Arch Orthop Unfallchir       Date:  1975

2.  [Experimental investigation on histocompatibility of A1203 ceramic wear particles (author's transl)].

Authors:  P Griss; B Krempien; H von Andrian-Werburg; G Heimke; R Feiner
Journal:  Arch Orthop Unfallchir       Date:  1973

3.  Findings on total hip replacement for ten years. A retrospective multicentre study based on a 10% random sample of 39 000 total hip replacements after 10 years of observation.

Authors:  P Griss; M H Hackenbroch; M Jäger; B Preussner; T Schäfer; R Seebauer; W van Eimeren; W Winkler
Journal:  Aktuelle Probl Chir Orthop       Date:  1982

4.  New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramin/metal.

Authors:  M Semlitsch; M Lehmann; H Weber; E Doerre; H G Willert
Journal:  J Biomed Mater Res       Date:  1977-07

5.  [The Mannheimer oxide ceramic-metal composite hip prostheses (author's transl)].

Authors:  P Griss; E Werner; R Buchinger; G Heimke
Journal:  Arch Orthop Unfallchir       Date:  1977-01-21

6.  [Fatigue strength of ceramic hip endoprostheses (author's transl)].

Authors:  E Dörre; W Dawihl; G Altmeyer
Journal:  Biomed Tech (Berl)       Date:  1977 Jan-Feb       Impact factor: 1.411

7.  Five years experience with ceramic-metal-composite hip endoprostheses. II. Mechanical evaluations and improvements.

Authors:  G Heimke; P Griss
Journal:  Arch Orthop Trauma Surg       Date:  1981

8.  [What is the significance of calcar resorption after total hip replacement (author's transl)].

Authors:  P Griss; G Heimke; E Werner; J Bleicher; G Jentschura
Journal:  Arch Orthop Trauma Surg       Date:  1978-10-27

9.  [Mechanical and tribological properties of ceramic endoprostheses (totalhips) (author's transl)].

Authors:  E Dörre; W Dawihl
Journal:  Biomed Tech (Berl)       Date:  1978-12       Impact factor: 1.411

10.  [Clinical relevance of signs of looseness in a hip prosthesis].

Authors:  U Buchhorn; P Griss; P G Niederer; H G Willert
Journal:  Z Orthop Ihre Grenzgeb       Date:  1979-08
View more
  8 in total

1.  The ceramic cup type Lindenhof. Results 10-14 years after implantation.

Authors:  H Gierse; B Maaz; C Hofer; S Gruner
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

2.  Five years experience with ceramic-metal-composite hip endoprostheses. II. Mechanical evaluations and improvements.

Authors:  G Heimke; P Griss
Journal:  Arch Orthop Trauma Surg       Date:  1981

3.  The bonding of glass ceramics to bone.

Authors:  T Kitsugi; T Yamamuro; T Nakamura; T Kokubo
Journal:  Int Orthop       Date:  1989       Impact factor: 3.075

4.  How safe are ceramic heads as hip endoprostheses? A series of three head fractures within 3 months.

Authors:  A Burckhardt; C Berberat
Journal:  Arch Orthop Trauma Surg       Date:  1993       Impact factor: 3.067

Review 5.  [Fracture of the ceramic head in total hip prosthesis. Apropos of 2 cases].

Authors:  P Mangione; X Pascarel; B Vinciguerra; J L Honton
Journal:  Int Orthop       Date:  1994       Impact factor: 3.075

Review 6.  [The problem of fractures of ceramic heads. What should be done?].

Authors:  H R Dürr
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

7.  Reconstruction of the acetabulum in THA using femoral head autografts in developmental dysplasia of the hip.

Authors:  Markus D Schofer; Thomas Pressel; Jan Schmitt; Thomas J Heyse; Ulrich Boudriot
Journal:  J Orthop Surg Res       Date:  2011-06-22       Impact factor: 2.359

8.  Third-generation pure alumina and alumina matrix composites in total hip arthroplasty: What is the evidence?

Authors:  Didier Hannouche; Matthieu Zingg; Hermes Miozzari; Remy Nizard; Anne Lübbeke
Journal:  EFORT Open Rev       Date:  2018-01-10
  8 in total