Literature DB >> 7217116

Stress fields in the unplated and plated canine femur calculated from in vivo strain measurements.

D R Carter, R Vasu, D M Spengler, R T Dueland.   

Abstract

Entities:  

Mesh:

Year:  1981        PMID: 7217116     DOI: 10.1016/0021-9290(81)90081-6

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


× No keyword cloud information.
  6 in total

1.  Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates.

Authors:  V K Ganesh; K Ramakrishna; Dhanjoo N Ghista
Journal:  Biomed Eng Online       Date:  2005-07-27       Impact factor: 2.819

2.  Mechanical loading histories and cortical bone remodeling.

Authors:  D R Carter
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

3.  Bone remodeling due to continuously applied loads.

Authors:  J B Meade; S C Cowin; J J Klawitter; W C Van Buskirk; H B Skinner
Journal:  Calcif Tissue Int       Date:  1984       Impact factor: 4.333

4.  A strain-gauge study of the effect of external fixation on the canine tibia.

Authors:  K J Matushek; G Sumner-Smith; J Schatzker; T C Hearn; C Taves; J Hoare
Journal:  Arch Orthop Trauma Surg       Date:  1989       Impact factor: 3.067

5.  Angle stable nails provide improved healing for a complex fracture model in the femur.

Authors:  Meghan R Kubacki; Christopher A Verioti; Savan D Patel; Adam N Garlock; David Fernandez; Patrick J Atkinson
Journal:  Clin Orthop Relat Res       Date:  2013-09-19       Impact factor: 4.176

6.  Low-magnitude high-frequency mechanical signals accelerate and augment endochondral bone repair: preliminary evidence of efficacy.

Authors:  Allen E Goodship; Timothy J Lawes; Clinton T Rubin
Journal:  J Orthop Res       Date:  2009-07       Impact factor: 3.494

  6 in total