Literature DB >> 2730298

A strain-gauge study of the effect of external fixation on the canine tibia.

K J Matushek1, G Sumner-Smith, J Schatzker, T C Hearn, C Taves, J Hoare.   

Abstract

Electrical resistance rosette strain gauges bonded directly to the surface of the midshaft of the normal canine tibia were utilized to study the effect of the AO external skeletal fixator on the magnitude and orientation of the peak strain values recorded during locomotion. The application of the fixator in a single lateral bar configuration resulted in a significant decrease in surface bone strain magnitude but in only minor changes in the orientation of those strains. However, in only one of three dogs tested did the addition of a second external connecting bar result in significant further decreases in bone strain.

Entities:  

Mesh:

Year:  1989        PMID: 2730298     DOI: 10.1007/bf00934260

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  17 in total

1.  Implantation of strain gages on bone in vivo.

Authors:  G V Cochran
Journal:  J Biomech       Date:  1972-01       Impact factor: 2.712

2.  Effects of internal fixation plates on mechanical deformation of bone.

Authors:  G V Cochran
Journal:  Surg Forum       Date:  1969

3.  An interdisciplinary approach to evaluate the effect of internal fixation plate on long bone remodeling.

Authors:  S L Woo; B R Simon; W H Akeson; M P McCarty
Journal:  J Biomech       Date:  1977       Impact factor: 2.712

4.  Strain gauge analysis of bone response to internal fixation.

Authors:  J Schatzker; G Sumner-Smith; R Clark; R McBroom
Journal:  Clin Orthop Relat Res       Date:  1978-05       Impact factor: 4.176

5.  Evaluation of tension and compression forces in the canine femur in vivo.

Authors:  P A Manley; J Schatzker; G Sumner-Smith
Journal:  Arch Orthop Trauma Surg       Date:  1982

6.  Effect of internal fixation on the strain environment of the canine femur.

Authors:  P A Manley; J Schatzker; G Sumner-Smith
Journal:  Arch Orthop Trauma Surg       Date:  1982

7.  A quantitative assessment of compression plate fixation in vivo: an experimental study using the sheep radius.

Authors:  D G Baggott; A E Goodship; L E Lanyon
Journal:  J Biomech       Date:  1981       Impact factor: 2.712

8.  Measurement of fracture gap motion in external fixation.

Authors:  D Seligson; G Powers; P O'Connell; M H Pope
Journal:  J Trauma       Date:  1981-09

9.  Experimental analysis of Hoffmann external fixation in various mountings.

Authors:  H A Schrøder; R E Weeth; T Madsen
Journal:  Arch Orthop Trauma Surg       Date:  1985

10.  Fractures of the tibia treated by flexible external fixation.

Authors:  A Schmidt; C H Rorabeck
Journal:  Clin Orthop Relat Res       Date:  1983-09       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.