Literature DB >> 7191990

Tissue compliance in superficial tissues along body axis in man.

K A Kirsch, J Merke, N Rambo, H J Wicke.   

Abstract

A previously described miniature plethysmograph which allowed the measurement of tissue volumes in superficial tissues was enclosed in a small plexiglass chamber and attached to the frontal area, sternum, dorsum and the tibia. The tissues interposed between bone and skin underneath the chamber were exposed to pressures between +/- 3 and +/- 15 mmHg in order to test tissue deformability. The pressure application induced within the first 5 s a fast component of tissue deformation comprising between 75-90% of the total deformation followed by a slow component which lasted till the end of the pressure application. The highest deformability was found in the tissues of the sternum and dorsum whereas the stiffest tissues were in the pretibial area. Assuming the tissue deformation is due to a translocation of fluid into or out of the pressurized tissue, the tissue compliance was calculated. This calculated tissue compliance was 19.2 ml . 1,000 ml-1 . mmHg-1 in the sternum and 6.4 ml . 1,000 ml-1 . mmHg-1 (P < 0.01) in the pretibial area applying a pressure of +/- 3 mmHg. The differences observed are due to the morphological arrangement of the tissue fibres which in turn have to counteract the gravity forces to which the tissues are usually exposed during upright standing.

Entities:  

Mesh:

Year:  1980        PMID: 7191990     DOI: 10.1007/bf00580976

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  20 in total

1.  Tissue mechanics.

Authors:  R M Kenedi; T Gibson; J H Evans; J C Barbenel
Journal:  Phys Med Biol       Date:  1975-09       Impact factor: 3.609

2.  On the capacity and distensibility of the blood vessels of the human forearm.

Authors:  A D GREENFIELD; G C PATTERSON
Journal:  J Physiol       Date:  1956-02-28       Impact factor: 5.182

3.  A DIRECT METHOD FOR THE ESTIMATION OF SKIN DISTENSIBILITY WITH ITS APPLICATION TO THE STUDY OF VASCULAR STATES.

Authors:  W A Sodeman; G E Burch
Journal:  J Clin Invest       Date:  1938-11       Impact factor: 14.808

4.  Protein concentration and colloid osmotic pressure of interstitial fluid collected by the wick technique: analysis and evaluation of the method.

Authors:  H O Fadnes; K Aukland
Journal:  Microvasc Res       Date:  1977-07       Impact factor: 3.514

Review 5.  Physiological effects of locally applied reduced pressure in man.

Authors:  R A Wolthuis; S A Bergman; A E Nicogossian
Journal:  Physiol Rev       Date:  1974-07       Impact factor: 37.312

Review 6.  Editorial: Autoregulation of interstitial fluid volume. Edema-preventing mechanisms.

Authors:  K Aukland
Journal:  Scand J Clin Lab Invest       Date:  1973-05       Impact factor: 1.713

7.  Renal control of changes in the compliance of the interstitial space: a factor in the aetiology of renoprival hypertension.

Authors:  J Lucas; M A Floyer
Journal:  Clin Sci       Date:  1973-04       Impact factor: 6.124

8.  Negative pressure in the interstitial fluid of animals. Fluid tensions are spectacular in plants; in animals they are elusively small, but just as vital.

Authors:  P F Scholander; A R Hargens; S L Miller
Journal:  Science       Date:  1968-07-26       Impact factor: 47.728

9.  Investigations of transvascular plasma passage with fluorescent microscopic technique.

Authors:  S Witte
Journal:  Bibl Anat       Date:  1965

10.  Dynamics of transcapillary fluid exchange.

Authors:  C A Wiederhielm
Journal:  J Gen Physiol       Date:  1968-07-01       Impact factor: 4.086

View more
  2 in total

Review 1.  Use of knee braces in sport. Current recommendations.

Authors:  J P Albright; A Saterbak; J Stokes
Journal:  Sports Med       Date:  1995-11       Impact factor: 11.136

2.  Influence of quantified dry cupping on soft tissue compliance in athletes with myofascial pain syndrome.

Authors:  Yen-Chun Chiu; Ioannis Manousakas; Shyh Ming Kuo; Jen-Wen Shiao; Chien-Liang Chen
Journal:  PLoS One       Date:  2020-11-19       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.