Literature DB >> 7174701

Physiological pulsatile flow experiments in a model of the human aortic arch.

T L Yearwood, K B Chandran.   

Abstract

An experimental investigation of physiologically relevant pulsatile flow in a model of the human aortic arch has been conducted. The model aortic arch flow chamber was fabricated in clear acrylic from an in situ casting of the human aorta and was incorporated in a mock-circulatory system. The model excluded the coronary sinuses and the three major branching arteries of the mid-arch region in order to concentrate only upon the effects of the multi-dimensional curvatures and tapering in the aorta. Furthermore, a flow straightening section was placed upstream to the flow chamber to eliminate any fluid disturbances created by the prosthetic aortic valve used in these studies. The qualitative flow visualization studies in the model aorta revealed the presence of strong secondary fluid motions near the inner wall. These helical flows dissipated during diastole, being greatly affected by the dramatic flow reversals which occurred along the inner wall at the onset of diastole. Quantitative studies were conducted using a three-sensor hot-film velocity probe to determine the axial, radial and tangential velocity components at various cross-sections in the aorta. The results showed rapid reversal of axial velocity near the inner wall at the onset of diastole.

Entities:  

Mesh:

Year:  1982        PMID: 7174701     DOI: 10.1016/0021-9290(82)90023-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Differences in aortic vortex flow pattern between normal and patients with stroke: qualitative and quantitative assessment using transesophageal contrast echocardiography.

Authors:  Jang-Won Son; Geu-Ru Hong; Woosol Hong; Minji Kim; Helene Houle; Mani A Vannan; Gianni Pedrizzetti; Namsik Chung
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 2.357

2.  A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta.

Authors:  S K Lam; George S K Fung; Stephen W K Cheng; K W Chow
Journal:  Med Biol Eng Comput       Date:  2008-07-11       Impact factor: 2.602

3.  Pulmonary blood velocity profile variability in open-chest dogs: influence of acutely altered hemodynamic states on profiles, and influence of profiles on the accuracy of techniques for cardiac output determination.

Authors:  C L Lucas; G W Henry; J I Ferreiro; B Ha; B A Keagy; B R Wilcox
Journal:  Heart Vessels       Date:  1988       Impact factor: 2.037

4.  Finite element analysis of helical flows in human aortic arch: a novel index.

Authors:  Cheng-Hung Lee; Kuo-Sheng Liu; Guan-Heng Jhong; Shih-Jung Liu; Ming-Yi Hsu; Chao-Jan Wang; Kuo-Chun Hung
Journal:  Biomicrofluidics       Date:  2014-04-09       Impact factor: 2.800

Review 5.  Functional assessment of thoracic aortic aneurysms - the future of risk prediction?

Authors:  Pouya Youssefi; Rajan Sharma; C Alberto Figueroa; Marjan Jahangiri
Journal:  Br Med Bull       Date:  2017-01-01       Impact factor: 4.291

6.  Fluid dynamics of coarctation of the aorta and effect of bicuspid aortic valve.

Authors:  Zahra Keshavarz-Motamed; Julio Garcia; Lyes Kadem
Journal:  PLoS One       Date:  2013-08-27       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.