Literature DB >> 7161283

Telemetering in vivo loads from nail plate implants.

R H Brown, A H Burstein, V H Frankel.   

Abstract

A system of multi-channel telemetry capable of broadcasting in vivo loading from orthopaedic implants is presented. Its use to monitor the two orthogonal bending moments about the nail plate junction of three implanted hip nails is described. Typical results from these cases in which the telemeterized implant was employed to treat proximal femoral fixation and osteotomy are given.

Mesh:

Year:  1982        PMID: 7161283     DOI: 10.1016/0021-9290(82)90046-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Elementary Implantable Force Sensor: For Smart Orthopaedic Implants.

Authors:  Rebecca A Wachs; David Ellstein; John Drazan; Colleen P Healey; Richard L Uhl; Kenneth A Connor; Eric H Ledet
Journal:  Adv Biosens Bioelectron       Date:  2013-12

Review 2.  Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review.

Authors:  Ali Jabran; Chris Peach; Lei Ren
Journal:  Biomed Eng Online       Date:  2018-04-27       Impact factor: 2.819

Review 3.  Wireless Technologies for Implantable Devices.

Authors:  Bradley D Nelson; Salil Sidharthan Karipott; Yvonne Wang; Keat Ghee Ong
Journal:  Sensors (Basel)       Date:  2020-08-16       Impact factor: 3.576

4.  Continuous Implant Load Monitoring to Assess Bone Healing Status-Evidence from Animal Testing.

Authors:  Markus Windolf; Viktor Varjas; Dominic Gehweiler; Ronald Schwyn; Daniel Arens; Caroline Constant; Stephan Zeiter; Robert Geoff Richards; Manuela Ernst
Journal:  Medicina (Kaunas)       Date:  2022-06-27       Impact factor: 2.948

Review 5.  Implantable sensor technology: measuring bone and joint biomechanics of daily life in vivo.

Authors:  Darryl D D'Lima; Benjamin J Fregly; Clifford W Colwell
Journal:  Arthritis Res Ther       Date:  2013-01-31       Impact factor: 5.156

6.  High-tech hip implant for wireless temperature measurements in vivo.

Authors:  Georg Bergmann; Friedmar Graichen; Jörn Dymke; Antonius Rohlmann; Georg N Duda; Philipp Damm
Journal:  PLoS One       Date:  2012-08-22       Impact factor: 3.240

7.  Critical factors in cut-out complication after Gamma Nail treatment of proximal femoral fractures.

Authors:  Alicja J Bojan; Claudia Beimel; Gilbert Taglang; David Collin; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2013-01-02       Impact factor: 2.362

8.  Comparison of the Sliding and Femoral Head Rotation among Three Different Femoral Head Fixation Devices for Trochanteric Fractures.

Authors:  Nobuaki Chinzei; Takafumi Hiranaka; Takahiro Niikura; Mitsuo Tsuji; Ryosuke Kuroda; Minoru Doita; Masahiro Kurosaka
Journal:  Clin Orthop Surg       Date:  2015-08-13

9.  Smart implants in orthopedic surgery, improving patient outcomes: a review.

Authors:  Eric H Ledet; Benjamin Liddle; Katerina Kradinova; Sara Harper
Journal:  Innov Entrep Health       Date:  2018-08-29

10.  Endurance testing and finite element simulation of a modified hip stem for integration of an energy harvesting system.

Authors:  Hans-E Lange; Rainer Bader; Daniel Kluess
Journal:  Proc Inst Mech Eng H       Date:  2021-06-17       Impact factor: 1.617

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.