Literature DB >> 7155942

Use of echocardiography in newborns with patent ductus arteriosus: a review.

H D Allen, S J Goldberg, L M Valdes-Cruz, D J Sahn.   

Abstract

Assessment of the contribution of left-to-right shunted ductal flow to the clinical state of a newborn with respiratory distress syndrome is difficult. Echocardiography has aided in the bedside diagnosis and management of these infants. M-mode echocardiography allows evaluation of left atrial dimension in both precordial and suprasternal planes, left ventricular dimension, and indices of function. M-mode echocardiography combined with saline contrast aortic injections allows a very sensitive demonstration of the presence of left-to-right shunting patent ductus arteriosus even if no murmur is present. Two-dimensional echocardiography demonstrates the physical appearance of the ductus and helps rule out associated congenital cardiac lesions. Incorporation of venous and arterial contrast injections help demonstrate flow direction as well. Range gated pulsed Doppler echocardiography helps evaluate flow characteristics and aids in differential diagnosis. In the future, ultrasonic evaluation will probably combine Doppler echocardiography with two-dimensional echocardiography allowing clearer noninvasive definition of anatomy and flow direction. None of these techniques should be used by itself. Careful clinical assessment by standard techniques along with judicious use of ultrasonic methodology should result in improved diagnosis and management.

Entities:  

Mesh:

Year:  1982        PMID: 7155942     DOI: 10.1007/BF02082335

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  21 in total

1.  Echocardiographic detection of large left to right shunts and cardiomyopathies in infants and children.

Authors:  D J Sahn; Y Vaucher; D E Williams; H D Allen; S J Goldberg; W F Friedman
Journal:  Am J Cardiol       Date:  1976-07       Impact factor: 2.778

Review 2.  Ultrasound cardiac diagnosis.

Authors:  H D Allen; L W Lange; D J Sahn; S J Goldberg
Journal:  Pediatr Clin North Am       Date:  1978-11       Impact factor: 3.278

3.  Echocardiographic assessment of ductus arteriosus shunt in premature infants.

Authors:  N H Silverman; A B Lewis; M A Heymann; A M Rudolph
Journal:  Circulation       Date:  1974-10       Impact factor: 29.690

4.  Use of time interval histographic output from echo-Doppler to detect left-to-right atrial shunts.

Authors:  S J Goldberg; J C Areias; S E Spitaels; V H de Villeneuve
Journal:  Circulation       Date:  1978-07       Impact factor: 29.690

5.  Lesions that cause aortic flow disturbance.

Authors:  S J Goldberg; J Areias; L Feldman; D J Sahn; H D Allen
Journal:  Circulation       Date:  1979-12       Impact factor: 29.690

6.  The silent ductus arteriosus.

Authors:  R L McGrath; G A McGuinness; G L Way; R R Wolfe; J J Nora; M A Simmons
Journal:  J Pediatr       Date:  1978-07       Impact factor: 4.406

7.  Echocardiographic detection and management of patent ductus arteriosus in neonates with respiratory distress syndrome: a two-and one-half year prospective study.

Authors:  S J Goldberg; H D Allen; D J Sahn
Journal:  J Clin Ultrasound       Date:  1977-06       Impact factor: 0.910

8.  Real-time cross-sectional echocardiographic imaging and measurement of the patent ductus arteriosus in infants and children.

Authors:  D J Sahn; H D Allen
Journal:  Circulation       Date:  1978-08       Impact factor: 29.690

9.  Diagnosis of ventricular septal defect by pulsed Doppler echocardiography. Sensitivity, specificity and limitations.

Authors:  J G Stevenson; I Kawabori; T Dooley; W G Guntheroth
Journal:  Circulation       Date:  1978-08       Impact factor: 29.690

10.  Echocardiographic diagnosis: pitfalls in the premature infant with a large patent ductus arteriosus.

Authors:  M J Hirschklau; T G DiSessa; C B Higgins; W F Friedman
Journal:  J Pediatr       Date:  1978-03       Impact factor: 4.406

View more
  3 in total

1.  Pulse wave patterns in patent ductus arteriosus.

Authors:  B P Lundell
Journal:  Arch Dis Child       Date:  1983-09       Impact factor: 3.791

2.  Pulmonary artery velocity patterns in ductus arteriosus.

Authors:  N Wilson; D F Dickinson; S J Goldberg; O Scott
Journal:  Br Heart J       Date:  1984-10

3.  Cross sectional echocardiography in determining persistent patency of the ductus arteriosus in preterm infants.

Authors:  M L Rigby; D Pickering; A Wilkinson
Journal:  Arch Dis Child       Date:  1984-04       Impact factor: 3.791

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.