Literature DB >> 632995

Echocardiographic diagnosis: pitfalls in the premature infant with a large patent ductus arteriosus.

M J Hirschklau, T G DiSessa, C B Higgins, W F Friedman.   

Abstract

Thirty-one infants with clinical and radiographic evidence of a large left-to-right shunt across a patent ductus arteriosus underwent echocardiographic study to determine the magnitude of shunting. Seven patients were found to have a normal-left atrial dimensions and a normal left atrial/aortic root dimension at the time when physical and roentgenographic findings of a large PDA were most pronounced. In contrast, left ventricular end diastolic dimensions were excessive in these infants. After ductal closure (four, surgery; two, indomethacin, one, spontaneous) the left ventricular end diastolic dimension fell to the normal range. Optimal echocardiographic accuracy in infants with PDA should combine analysis of both atrial and ventricular dimensions; the former, used alone, may be misleading.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 632995     DOI: 10.1016/s0022-3476(78)80452-1

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  12 in total

1.  Contrast echocardiographic assessment of the neonatal ductus arteriosus.

Authors:  D B Knight; V Y Yu
Journal:  Arch Dis Child       Date:  1986-05       Impact factor: 3.791

Review 2.  Diagnosis of patent ductus arteriosus in the preterm newborn.

Authors:  N Evans
Journal:  Arch Dis Child       Date:  1993-01       Impact factor: 3.791

3.  Pulse wave patterns in patent ductus arteriosus.

Authors:  B P Lundell
Journal:  Arch Dis Child       Date:  1983-09       Impact factor: 3.791

4.  Patent ductus arteriosus in premature babies.

Authors:  M L Chiswick
Journal:  Br Med J (Clin Res Ed)       Date:  1981-12-05

Review 5.  Patent ductus arteriosus: current clinical status.

Authors:  J A Kitterman
Journal:  Arch Dis Child       Date:  1980-02       Impact factor: 3.791

6.  Pharmacological closure of ductus arteriosus in preterm infants using indomethacin.

Authors:  H I Obeyesekere; S Pankhurst; V Y Yu
Journal:  Arch Dis Child       Date:  1980-04       Impact factor: 3.791

7.  Use of echocardiography in newborns with patent ductus arteriosus: a review.

Authors:  H D Allen; S J Goldberg; L M Valdes-Cruz; D J Sahn
Journal:  Pediatr Cardiol       Date:  1982       Impact factor: 1.655

8.  Patent ductus arteriosus in infants of low birth weight.

Authors:  D R Smith; D H Cook; T Izukawa; P M Olley; P R Swyer; R D Rowe
Journal:  Can Med Assoc J       Date:  1980-10-18       Impact factor: 8.262

9.  Re-evaluation of the left atrial to aortic root ratio as a marker of patent ductus arteriosus.

Authors:  P Iyer; N Evans
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1994-03       Impact factor: 5.747

10.  Radionuclide angiographic and echocardiographic quantitation of left-to-right shunts in children with ventricular septal defect.

Authors:  J A Breitweser; M J Gelfand; R A Meyer; T Dillon; W Covitz; S Kaplan
Journal:  Pediatr Cardiol       Date:  1982       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.