Three-dimensional ballistocardiographic responses to changes of posture.

R W Soames, J Atha.   

Abstract

In an assessment of cardiovascular performance in eighteen young healthy adults, ballistocardiograms were recorded in three mutually perpendicular directions in both the supine and the seated postures, and in the head-foot direction when standing. From these recordings three-dimensional vector ballistocardiograms were obtained which were found to be consistent over repeated measurements (r = 0.81 to 0.88 for the three components when supine) and sensitive to the functional changes imposed by changes of posture. It was observed that in the antero-posterior ballistocardiogram recorded in the supine position there was, in the IJK complex, an additional peak and trough that was not present in any other directional, or postural, ballistocardiogram. This extra wave is held to reflect the directional change of blood flow in the arch of the aorta due to its sagittal curvature around the trachea and vertebral column. From these three-dimensional recordings the functional mechanical axis of the heart was determined for both the supine and seated positions. although similar these axes were not collinear, there being an 8 degrees greater tilt in both the rightward (29 degrees: 21 degrees) and the posterior (28 degrees: 20 degrees) direction in the seated position.

Mesh:

Year:  1982        PMID: 7140155     DOI: 10.1088/0143-0815/3/3/001

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  5 in total

1.  Short and longer term repeatability of ballistocardiography in a sitting position with EMFi sensor.

Authors:  Jarmo Alametsä; Ari Palomäki; Jari Viik
Journal:  Med Biol Eng Comput       Date:  2011-02-19       Impact factor: 2.602

2.  Ballistocardiography--a method worth revisiting.

Authors:  Laurent Giovangrandi; Omer T Inan; Richard M Wiard; Mozziyar Etemadi; Gregory T A Kovacs
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

3.  Kinocardiography Derived from Ballistocardiography and Seismocardiography Shows High Repeatability in Healthy Subjects.

Authors:  Amin Hossein; Jérémy Rabineau; Damien Gorlier; Jose Ignacio Juarez Del Rio; Philippe van de Borne; Pierre-François Migeotte; Antoine Nonclercq
Journal:  Sensors (Basel)       Date:  2021-01-26       Impact factor: 3.576

4.  Force plate monitoring of human hemodynamics.

Authors:  Jan Kríz; Petr Seba
Journal:  Nonlinear Biomed Phys       Date:  2008-02-22

5.  Closed-Loop Multiscale Computational Model of Human Blood Circulation. Applications to Ballistocardiography.

Authors:  Jeremy Rabineau; Antoine Nonclercq; Tim Leiner; Philippe van de Borne; Pierre-Francois Migeotte; Benoit Haut
Journal:  Front Physiol       Date:  2021-12-09       Impact factor: 4.566

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.