Literature DB >> 711394

A proposed mechanism for transient increases in arterial pressure and flow during angiographic injections.

G L Wolf, D D Shaw, H A Baltaxe, K Kilzer, L Kraft.   

Abstract

In a series of animal experiments, we have confirmed the observation that arterial pressure and flow increase distal to the injection site during power injections through non-obstructing catheters. Our data suggest that the phenomenon is secondary to the transient production of turbulence. Thus, for a given injection rate, catheters with smaller end holes create more fluid velocity, which increases the Reynolds number and causes augmentation of downstream pressure and flow. The addition of side holes decreases the fluid velocity of the injectate and minimizes the hemodynamic effects. The discussion deals with factors contributing to the generation of local turbulence, the magnitude of pressure and flow changes caused by the injections, and the clinical implications of these artifacts.

Mesh:

Substances:

Year:  1978        PMID: 711394     DOI: 10.1097/00004424-197805000-00004

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  8 in total

1.  The mixability of angiographic contrast with arterial blood.

Authors:  Baruch B Lieber; Chander Sadasivan; Qing Hao; Jaehoon Seong; Liliana Cesar
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

2.  Angiographic assessment of the efficacy of flow diverter treatment for cerebral aneurysms.

Authors:  Chander Sadasivan; Ronak Dholakia; Lissa Peeling; Philipp Gölitz; Arnd Doerfler; Baruch B Lieber; David J Fiorella; Henry H Woo
Journal:  Interv Neuroradiol       Date:  2019-07-11       Impact factor: 1.610

3.  Doppler-sonographic examination of the arterial flow in the carotid and supratrochlear arteries during carotid angiography.

Authors:  P Stoeter; N Prey; C Hoffmann; H J Büdingen; R Bergleiter
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

4.  Hemodynamic effects of rapid injection into the canine superior mesenteric artery.

Authors:  E D Jacobson; C Eldon; J D Fondacaro
Journal:  Dig Dis Sci       Date:  1981-10       Impact factor: 3.199

5.  The imaging of myocardial perfusion with 81mKr during coronary arteriography.

Authors:  P H Kleynhans; M G Lötter; A van Aswegen; C P Herbst; J D Marx; P C Minnaar
Journal:  Eur J Nucl Med       Date:  1982

6.  Effects of a rapid injection into the canine superior mesenteric artery of diatrizoate meglumine and diatrizoate sodium (Renografin-76).

Authors:  E D Jacobson; C Eldon; J D Fondacaro
Journal:  Cardiovasc Intervent Radiol       Date:  1980       Impact factor: 2.740

7.  An in vitro study of pressure increases during contrast injections in diagnostic cerebral angiography.

Authors:  Samantha Marfoglio; Brandon Kovarovic; Wei Hou; David J Fiorella; Chander Sadasivan
Journal:  Interv Neuroradiol       Date:  2021-02-25       Impact factor: 1.764

8.  Effect of saline injection mixing on accuracy of conductance lumen sizing of peripheral vessels.

Authors:  Hyo Won Choi; Benjamin Jansen; David Birrer; Ghassan S Kassab
Journal:  PLoS One       Date:  2013-09-13       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.