Literature DB >> 7108615

Interpretation of multigated Fourier functional images.

R E Wendt, P H Murphy, J W Clark, J A Burdine.   

Abstract

First-harmonic Fourier analysis is currently used to aid in the interpretation of multigated cardiac studies. Its intrinsic inaccuracies are not generally appreciated. This study investigates the characteristics and magnitudes of the errors of this technique. The study analyzes computer-generated phantoms that isolate the various motions of the ventricles (contraction, translation, and rotation) with the first-harmonic approach. The first-harmonic output is compared with a more accurate fitting scheme using multiple terms of the Fourier expansion. Significant artifacts of the inaccuracy of the first harmonic appear in the phantom studies and are observed in patient examples. We conclude that caution is needed in interpreting first-harmonic phase and amplitude images, and particularly in associating them with parameters like the onset of contraction and the stroke volume.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7108615

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  10 in total

1.  Cardiac gated equilibrium radionuclide angiography and multiharmonic Fourier phase analysis: optimal acquisition parameters in arrhythmogenic right ventricular cardiomyopathy.

Authors:  D Daou; R Lebtahi; M Faraggi; Y Petegnief; D Le Guludec
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

2.  Three monochrome displays from a single, true color video display controller.

Authors:  U Raff; V M Spitzer
Journal:  J Digit Imaging       Date:  1991-02       Impact factor: 4.056

Review 3.  First-pass radionuclide angiocardiography with single-crystal gamma cameras.

Authors:  K Nichols; E G DePuey; A Rozanski
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

4.  Ejection fraction by combined inverse Fourier analysis and second-derivative technique: correlation with isocontour method.

Authors:  S Balachandran; S Eason; L McGuire; S Bernard; C Boyd
Journal:  Eur J Nucl Med       Date:  1986

5.  Use of a nonstationary temporal Wiener filter in nuclear medicine.

Authors:  M A King; T R Miller
Journal:  Eur J Nucl Med       Date:  1985

6.  Recent developments of cardiac digital radiography.

Authors:  O Ratib; W Rutishauser
Journal:  Int J Card Imaging       Date:  1985

7.  Phase mapping of radionuclide gated biventriculograms in patients with sustained ventricular tachycardia or Wolff-Parkinson-White syndrome.

Authors:  D Le Guludec; M Bourguignon; C Sebag; H Valette; A Sirinelli; J M Davy; A Syrota; G Motte
Journal:  Int J Card Imaging       Date:  1987

8.  Characterization and automatic identification of ECG conduction abnormalities using segmental multiharmonic Fourier analysis of gated blood-pool scintigrams.

Authors:  J Machac; S F Horowitz; R Fagerstrom; R Levine; S J Goldsmith
Journal:  Eur J Nucl Med       Date:  1985

9.  Fourier analysis on ungated time-activity curves.

Authors:  J N Rioux; L Renaud; G Dupras
Journal:  Eur J Nucl Med       Date:  1985

10.  Quantitative assessment of cardiac mechanical synchrony using equilibrium radionuclide angiography.

Authors:  Harmandeep Singh; Abhinav Singhal; Punit Sharma; Chetan D Patel; Sandeep Seth; Arun Malhotra
Journal:  J Nucl Cardiol       Date:  2013-04-30       Impact factor: 5.952

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.