Literature DB >> 7105576

A retrospective study of Moore and Thompson hemiarthroplasty. A review of 599 surgical cases and an analysis of the technical complications.

D C Kwok, R L Cruess.   

Abstract

In a retrospective review of 580 patients with 599 hemiarthroplasties of the hip, 454 operations (75.8%) were carried out as primary procedures for fresh intracapsular fractures, and 145 operations (24.2%) were performed as salvage procedures. The three-month mortality rate was 5.0%, and the dislocation rate was 5.3%. The early results were assessed by roentgenograms alone; head size, neck length, stem-shaft angle, and calcar seating were measured on preoperative and postoperative films. Anteversion and retroversion could not be accurately assessed. Using an arbitrary rating system, the results were graded as excellent on the basis of four anatomical criteria: good, on the basis of three; fair, of two; and poor, on only one or none. Only 173 prostheses (26.3%) were graded as excellent and 103 (27.3%) as good. At least 70 (25.3%) were just fair, and 31 (11.2%) were poor. Inappropriate neck length was present in 55.0% of the dislocated prostheses, incorrect head size in 25.0%, varus of the prosthesis in 20.0%, and poor calcar seating in 25.0%. Thus, technical errors account for a significant number of imperfect hemiarthroplasties of the hip. Careful attention to detail should decrease the incidence of errors and improve end-results.

Entities:  

Mesh:

Year:  1982        PMID: 7105576

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  9 in total

1.  Intra-operative implantation errors during hemiarthroplasty.

Authors:  Dd Mue; Wt Yongu; H Mohammad; Jn Kortor; Ic Elachi; Jo Donwa
Journal:  J West Afr Coll Surg       Date:  2012-10

2.  Inpatient procedures in elderly women: an analysis over time.

Authors:  Sallie S Oliphant; Chiara Ghetti; Richard L McGough; Li Wang; Clareann H Bunker; Jerry L Lowder
Journal:  Maturitas       Date:  2013-05-23       Impact factor: 4.342

3.  The Exeter bipolar prosthesis in the active elderly patient: the results at 7 years.

Authors:  M F Pearse; S Bande; K J O'Dwyer; R S Ling
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

4.  The value of a special surgical team in preventing complications in the treatment of hip fractures.

Authors:  M J Parker; G A Pryor; J W Myles
Journal:  Int Orthop       Date:  1994-06       Impact factor: 3.075

5.  Distal Radius Isoelastic Resurfacing Prosthesis: A Preliminary Report.

Authors:  Satoshi Ichihara; Juan José Hidalgo Díaz; Brett Peterson; Sybille Facca; Frédéric Bodin; Philippe Liverneaux
Journal:  J Wrist Surg       Date:  2015-08

6.  Pre-operative templating for trauma hemiarthroplasty (Thompson's).

Authors:  Robert Nicholas Green; Paul R P Rushton; Derek Kramer; Dominic Inman; Paul F Partington
Journal:  J Orthop       Date:  2015-05-29

7.  Mechanical failure of a Thompson's hemiarthoplasty stem 28 years post-implantation: an investigation with electron microscopy.

Authors:  Ioannis Maris; Spyros Darmanis; Victor Kytopoulos; Angela Economakis; Konstantinos Kazakos
Journal:  J Mater Sci Mater Med       Date:  2007-02-01       Impact factor: 4.727

8.  High conversion rate to total hip arthroplasty after hemiarthroplasty in young patients with a minimum 10 years follow-up.

Authors:  Nam Hoon Moon; Won Chul Shin; Min Uk Do; Sang Woo Kang; Sang-Min Lee; Kuen Tak Suh
Journal:  BMC Musculoskelet Disord       Date:  2021-03-12       Impact factor: 2.362

9.  The BHU bicentric bipolar prosthesis in fracture neck femur in active elderly.

Authors:  Anil K Rai; Rakesh Agarwal; Saurabh Singh; Ratnav Ratan
Journal:  J Trauma Manag Outcomes       Date:  2008-09-25
  9 in total