Literature DB >> 7086787

Audit in a diabetic clinic.

D F Child, C P Williams.   

Abstract

Diabetic control was assessed in 82 established insulin-dependent diabetics using a microcapillary system for home preprandial blood glucose sampling. At initial assessment control in the majority (62%) was found to be unsatisfactory (at least 1 preprandial blood glucose greater than 13.0 mmol/l or frequent and severe hypoglycaemia). Sixty-three of these patients were assessed on more than one occasion. Only 24% were satisfactorily controlled at their first assessment, but this proportion had risen to 60% after 12 months. The ability of patients to perform unsupervised blood glucose levels using Ames Glucometers or BM-Glycemie 20-800 test strips was also assessed: 86% of the meter results were within one-third of the laboratory-based results, but there was evidence of bias towards the under-reading of higher glucose values using BM-Glycemie 20-800 test strips. Random blood glucose estimations performed in the diabetic clinic were of little value.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7086787      PMCID: PMC1437977          DOI: 10.1177/014107688207500606

Source DB:  PubMed          Journal:  J R Soc Med        ISSN: 0141-0768            Impact factor:   18.000


  9 in total

1.  Performance of blood-glucose strips.

Authors:  P M Lawson; C M Kesson; J T Ireland
Journal:  Lancet       Date:  1979-10-06       Impact factor: 79.321

2.  Home blood-glucose measurements without reflectance meter.

Authors:  S Walford; P Clarke; R Paisey; M Hartog; S P Allison
Journal:  Lancet       Date:  1980-03-22       Impact factor: 79.321

3.  Home blood glucose monitoring.

Authors:  R B Tattersall
Journal:  Diabetologia       Date:  1979-02       Impact factor: 10.122

4.  Onset and progression of diabetic glomerulosclerosis; a prospective study based on serial renal biopsies.

Authors:  E Takazakura; Y Nakamoto; H Hayakawa; K Kawai; S Muramoto
Journal:  Diabetes       Date:  1975-01       Impact factor: 9.461

5.  The influence of renal threshold on the interpretation of urine tests for glucose in diabetic patients.

Authors:  S Walford; M M Page; S P Allison
Journal:  Diabetes Care       Date:  1980 Nov-Dec       Impact factor: 19.112

6.  Hyperglycaemia and diabetes mellitus.

Authors:  R J Jarrett; H Keen
Journal:  Lancet       Date:  1976-11-06       Impact factor: 79.321

7.  Home monitoring of blood-glucose. Method for improving diabetic control.

Authors:  P H Sönksen; S L Judd; C Lowy
Journal:  Lancet       Date:  1978-04-08       Impact factor: 79.321

8.  Self-monitoring of blood-glucose. Improvement of diabetic control.

Authors:  S Walford; E A Gale; S P Allison; R B Tattersall
Journal:  Lancet       Date:  1978-04-08       Impact factor: 79.321

9.  A novel five-microlitre capillary system for home glucose monitoring.

Authors:  C P Williams; G K Davies; D F Child
Journal:  Ann Clin Biochem       Date:  1981-09       Impact factor: 2.057

  9 in total