Literature DB >> 76745

Home monitoring of blood-glucose. Method for improving diabetic control.

P H Sönksen, S L Judd, C Lowy.   

Abstract

64 diabetic patients measured their own blood-glucose concentration with "Dextrostix' (Ames) and an 'Eyetone' (Ames) meter. The records made at home by 53 of these patients have shown that this led to a significant improvement in blood-glucose control. A majority (64%) were able to maintain "good" control (80% of blood-glucose recordings equal to or less than 10 mmol/l for periods as long as 478 days). This hitherto unobtainable degree of control of blood-glucose was achieved mostly with conventional insulin regimens of twice-daily 'Actrapid' (Novo Laboratories Ltd.) and 'Leo-Retard' (Leo Laboratories Ltd.). Adjustments of insulin dosage and type were found to be much easier and more predictable than with urine-glucose analysis. No significant complications were encountered. Hypoglycaemic episodes were less frequent. 70% of patients preferred blood-tests to urine tests and 92% would like to buy their own meter "if the price was right." The results suggest that self-monitoring of blood-glucose by diabetics makes possible, for the first time, the achievement of near normoglycaemia. This may reduce the incidence of long-term diabetic complications.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 76745     DOI: 10.1016/s0140-6736(78)90854-1

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  64 in total

Review 1.  Role of self-monitoring of blood glucose in glycemic control.

Authors:  Andrew J Karter
Journal:  Endocr Pract       Date:  2006 Jan-Feb       Impact factor: 3.443

2.  Regulation of medical devices used in diabetology in Europe: time for reform?

Authors:  A J M Boulton; S Del Prato
Journal:  Diabetologia       Date:  2012-05-16       Impact factor: 10.122

3.  Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study.

Authors:  S Martin; B Schneider; L Heinemann; V Lodwig; H-J Kurth; H Kolb; W A Scherbaum
Journal:  Diabetologia       Date:  2005-12-17       Impact factor: 10.122

4.  Recent advances in continuous glucose monitoring: biocompatibility of glucose sensors for implantation in subcutis.

Authors:  Peter H Kvist; Henrik E Jensen
Journal:  J Diabetes Sci Technol       Date:  2007-09

5.  Problems and practical solutions in the external quality control of point of care devices with respect to the measurement of blood glucose.

Authors:  William Graham Wood
Journal:  J Diabetes Sci Technol       Date:  2007-03

Review 6.  To bridge science and patient care in diabetes.

Authors:  M Berger
Journal:  Diabetologia       Date:  1996-07       Impact factor: 10.122

7.  A randomised controlled trial of patient self management of oral anticoagulation treatment compared with primary care management.

Authors:  D A Fitzmaurice; E T Murray; K M Gee; T F Allan; F D R Hobbs
Journal:  J Clin Pathol       Date:  2002-11       Impact factor: 3.411

8.  Multivariate analysis of glycosylated haemoglobin in insulin-treated diabetics.

Authors:  D F Child; J Wood; P R Hudson; C P Williams; D R Roberts; C Smith
Journal:  J R Soc Med       Date:  1985-07       Impact factor: 5.344

9.  Impact of home blood glucose monitoring on childhood diabetes.

Authors:  J H Baumer; A D Edelsten; B C Howlett; C Owens; C A Pennock; D C Savage
Journal:  Arch Dis Child       Date:  1982-03       Impact factor: 3.791

Review 10.  Self-monitoring of blood glucose as part of the integral care of type 2 diabetes.

Authors:  Eleni I Boutati; Sotirios A Raptis
Journal:  Diabetes Care       Date:  2009-11       Impact factor: 19.112

View more