Literature DB >> 7071140

The recombination correction for an ionisation chamber exposed to pulsed radiation in a 'swept beam' technique. I. Theory.

J W Boag.   

Abstract

The established theory for the collection efficiency of an ionisation chamber irradiated by a series of uniform short pulses is extended to the more complex case of irradiation in a pulsed and electromagnetically swept electron beam. The radial variation of exposure rate is assumed to be Gaussian with scale constant equal to alpha, and the pulses are assumed to be uniformly distributed over the area swept out. A formula for the collection efficiency is derived and the influence of varying some of the parameters is studied. The collection efficiency, phi 1, at voltage V1 can be calculated if the two dosemeter readings, Q1 and Q2, at two widely different chamber voltages, V1 and V2, are known. phi 1 depends primarily upon the ratios Q1/Q2 and V1/V2 and to a much lesser extent upon the geometry of the chamber or the ratio of Gaussian scale constant to a typical linear dimension of the field scanned. Charts for calculating phi 1 are provided.

Entities:  

Mesh:

Year:  1982        PMID: 7071140     DOI: 10.1088/0031-9155/27/2/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Not a slippery slope or sudden subversion: German medicine and national socialism in 1933.

Authors:  H M Hanauske-Abel
Journal:  BMJ       Date:  1996-12-07

2.  Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.

Authors:  Liyong Lin; Minglei Kang; Timothy D Solberg; Thierry Mertens; Christian Baeumer; Christopher G Ainsley; James E McDonough
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

3.  Ion recombination correction factors (P(ion)) for Varian TrueBeam high-dose-rate therapy beams.

Authors:  Stephen F Kry; Richard Popple; Andrea Molineu; David S Followill
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

4.  Out-of-Field Dose Calculation by a Commercial Treatment Planning System and Comparison by Monte Carlo Simulation for Varian TrueBeam®.

Authors:  N S Shine; Raghukumar Paramu; M Gopinath; R C Jaon Bos; P M Jayadevan
Journal:  J Med Phys       Date:  2019 Jul-Sep

5.  Ultrahigh dose rate pencil beam scanning proton dosimetry using ion chambers and a calorimeter in support of first in-human FLASH clinical trial.

Authors:  Eunsin Lee; Ana Mónica Lourenço; Joseph Speth; Nigel Lee; Anna Subiel; Francesco Romano; Russell Thomas; Richard A Amos; Yongbin Zhang; Zhiyan Xiao; Anthony Mascia
Journal:  Med Phys       Date:  2022-07-14       Impact factor: 4.506

6.  The Metrology of a Rastered Spot of X Rays used in Security Screening.

Authors:  Lawrence T Hudson; Jack L Glover; Ronaldo Minniti
Journal:  J Res Natl Inst Stand Technol       Date:  2014-11-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.