Literature DB >> 7068332

Use of Fieldmaster automated perimeter for the detection of early visual field changes in glaucoma.

C Hong, Y Kitazawa, S Shirato.   

Abstract

The efficacy of automated suprathreshold perimetry with Fieldmaster automated perimeter (model 101 PR and 200) was evaluated in the screening for very early glaucomatous visual field defects which failed to be detected with kinetic perimetry using a Goldman perimeter. Evaluation of 117 eyes with elevated intraocular pressure revealed a small, relative defect in the central field in 14 eyes which was confirmed by static perimetry with a Tübinger perimeter. Although Fieldmaster model 200 is equipped with more target positions than model 101 PR, detectability of early defects was almost identical between two models. Automated suprathreshold perimetry with either model of Fieldmaster perimeter is useful in detecting the early changes which may be missed by kinetic perimetry with a Goldman perimeter. Based on the difference in the false positive rate (45.6% with model 200 vs 26.7% with model 101 PR) the screening with 101 PR seems to be more rewarding.

Entities:  

Mesh:

Year:  1982        PMID: 7068332     DOI: 10.1007/bf00161905

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  8 in total

1.  AUTOMATIC DEVICE FOR RAPID ASSESSMENT OF THE CENTRAL VISUAL FIELD.

Authors:  W M BUCHANAN; J GLOSTER
Journal:  Br J Ophthalmol       Date:  1965-02       Impact factor: 4.638

2.  Studies on computerized perimetry.

Authors:  A Heijl
Journal:  Acta Ophthalmol Suppl       Date:  1977

3.  Early visual field disturbances in glaucoma.

Authors:  E B Werner; S M Drance
Journal:  Arch Ophthalmol       Date:  1977-07

4.  Suprathreshold static perimetry. Initial clinical trials with the Fieldmaster automated perimeter.

Authors:  J L Keltner; C A Johnson; F G Balestrery
Journal:  Arch Ophthalmol       Date:  1979-02

5.  Single and multiple stimulus static perimetry in glaucoma; the two phases of perimetry. Thesis.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1973-10-12       Impact factor: 2.379

6.  Comparative evaluation of the Autofield-I, CFA-120, and Fieldmaster Model 101-PR automated perimeters.

Authors:  C A Johnson; J L Keltner
Journal:  Ophthalmology       Date:  1980-08       Impact factor: 12.079

7.  Suprathreshold static perimetry in glaucoma and other optic nerve disease.

Authors:  C A Johnson; J L Keltner; F G Balestrery
Journal:  Ophthalmology       Date:  1979-07       Impact factor: 12.079

8.  Automatic perimetry in glaucoma visual field screening. A clinical study.

Authors:  A Heijl
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1976-07-26
  8 in total
  3 in total

1.  Programmed visual field testing.

Authors:  D R Anderson
Journal:  Trans Am Ophthalmol Soc       Date:  1982

2.  The fieldmaster 101 PR automatic visual field screener--technical evaluation and clinical results.

Authors:  R W de Boer; T J van den Berg; E L Greve; H J Bos
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

3.  Performance of computer assisted perimeters.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.