Literature DB >> 7047551

Comparison of fluorescent and colorigenic substrates for enzyme immunoassays.

R H Yolken, F J Leister.   

Abstract

A variety of substrates can be employed in enzyme immunoassays (EIAs) for the measurement of enzyme-labeled immunoreactants. We compared the sensitivities of a fluorescent and a colorigenic substrate in an EIA system for the measurement of Haemophilus influenza purified polyribose phosphate. After a 10-min substrate incubation, the EIA in which the fluorescent substrate was used could detect 10 pg of polyribose phosphate per ml, whereas the EIA in which the colorigenic substrate was used required the addition of 640 pg of polyribose phosphate per ml to generate a positive reading. However, the use of longer substrate incubation periods led to an increase in sensitivity of the colorigenic EIA. After an incubation period of 240 min, the sensitivity was equal to that of the EIA in which the fluorescent substrate was used. These results suggest that the ultimate limit of sensitivity of EIA systems is determined by the nature of the antigen-antibody reactions. However, the use of high-energy substrates in EIA systems can allow for the attainment of maximal sensitivity after short enzyme-substrate incubation periods.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7047551      PMCID: PMC272186          DOI: 10.1128/jcm.15.5.757-760.1982

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

1.  Enzyme-linked fluorescence assay: Ultrasensitive solid-phase assay for detection of human rotavirus.

Authors:  R H Yolken; P J Stopa
Journal:  J Clin Microbiol       Date:  1979-09       Impact factor: 5.948

2.  Ultrasensitive enzymatic radioimmunoassay: application to detection of cholera toxin and rotavirus.

Authors:  C C Harris; R H Yolken; H Krokan; I C Hsu
Journal:  Proc Natl Acad Sci U S A       Date:  1979-10       Impact factor: 11.205

3.  Detection of Candida antigen in sera of patients with candidiasis by an enzyme-linked immunosorbent assay-inhibition technique.

Authors:  E Segal; R A Berg; P A Pizzo; J E Bennett
Journal:  J Clin Microbiol       Date:  1979-07       Impact factor: 5.948

4.  Light emission techniques for the microestimation of femtogram levels of peroxidase. Application to peroxidase (and other enzymes)-coupled antibody-cell antigen interactions.

Authors:  K Puget; A M Michelson; S Avrameas
Journal:  Anal Biochem       Date:  1977-05-01       Impact factor: 3.365

5.  The rapid determination of binding constants for antiviral antibodies by a radioimmunoassay. An analysis of the interaction between hybridoma proteins and influenza virus.

Authors:  M E Frankel; W Gerhard
Journal:  Mol Immunol       Date:  1979-02       Impact factor: 4.407

Review 6.  Enzyme-immunoassay.

Authors:  G B Wisdom
Journal:  Clin Chem       Date:  1976-08       Impact factor: 8.327

7.  More sensitive immunoassays.

Authors:  R Ekins
Journal:  Nature       Date:  1980-03-06       Impact factor: 49.962

8.  Indirect enzyme-linked immunosorbent assay for the quantitation of the type-specific antigen of Haemophilus influenzae b: a preliminary report.

Authors:  J Pepple; E R Moxon; R H Yolken
Journal:  J Pediatr       Date:  1980-08       Impact factor: 4.406

9.  Enzyme-linked immunosorbent assay (ELISA) for detection of human reovirus-like agent of infantile gastroenteritis.

Authors:  R H Yolken; H W Kim; T Clem; R G Wyatt; A R Kalica; R M Chanock; A Z Kapikian
Journal:  Lancet       Date:  1977-08-06       Impact factor: 79.321

10.  Enzyme-linked immunosorbent assay (ELISA): a practical tool for rapid diagnosis of viruses and other infectious agents.

Authors:  R H Yolken
Journal:  Yale J Biol Med       Date:  1980 Jan-Feb
View more
  12 in total

1.  Capillary enzyme immunoassay for rapid detection of herpes simplex virus in clinical specimens.

Authors:  I C Shekarchi; D A Fuccillo; R Strouse; J L Sever
Journal:  J Clin Microbiol       Date:  1987-02       Impact factor: 5.948

2.  Comparison of colorimetric, fluorescent, and enzymatic amplification substrate systems in an enzyme immunoassay for detection of DNA-RNA hybrids.

Authors:  F Coutlee; R P Viscidi; R H Yolken
Journal:  J Clin Microbiol       Date:  1989-05       Impact factor: 5.948

Review 3.  Rapid methods for the molecular diagnosis of infectious diseases: current trends and applications.

Authors:  P G Miotti
Journal:  Eur J Epidemiol       Date:  1987-12       Impact factor: 8.082

4.  Enzyme-linked immunosorbent assay detection of immunoglobulins G and M to Venezuelan equine encephalomyelitis virus in vaccinated and naturally infected humans.

Authors:  R R Rosato; F F Macasaet; P B Jahrling
Journal:  J Clin Microbiol       Date:  1988-03       Impact factor: 5.948

5.  Comparison of enzyme-linked immunosorbent assay with enzyme-linked fluorescence assay with automated readers for detection of rubella virus antibody and herpes simplex virus.

Authors:  I C Shekarchi; J L Sever; L Nerurkar; D Fuccillo
Journal:  J Clin Microbiol       Date:  1985-01       Impact factor: 5.948

6.  Detection of IgM antibodies against Chlamydia trachomatis by enzyme linked fluorescence immunoassay.

Authors:  K Numazaki; S Chiba; T Yamanaka; T Moroboshi; K Aoki; T Nakao
Journal:  J Clin Pathol       Date:  1985-07       Impact factor: 3.411

7.  Rapid detection of herpes simplex virus in clinical specimens by use of a capture biotin-streptavidin enzyme-linked immunosorbent assay.

Authors:  L S Nerurkar; M Namba; G Brashears; A J Jacob; Y J Lee; J L Sever
Journal:  J Clin Microbiol       Date:  1984-07       Impact factor: 5.948

8.  A vaccinia virus--herpes simplex virus (HSV) glycoprotein B1 recombinant or an HSV vaccine overcome the HSV type 2 induced humoral immunosuppression and protect against vaginal challenge in BALB/c mice.

Authors:  M Fleck; J Podlech; K Weise; D Falke
Journal:  Med Microbiol Immunol       Date:  1994-05       Impact factor: 3.402

9.  Quantitative studies of heat-stable proteinase from Pseudomonas fluorescens P1 by the enzyme-linked immunosorbent assay.

Authors:  S E Birkeland; L Stepaniak; T Sørhaug
Journal:  Appl Environ Microbiol       Date:  1985-02       Impact factor: 4.792

10.  Comparison of enzyme linked immunosorbent assay and enzyme linked fluorescence immunoassay for detection of antibodies against Chlamydia trachomatis.

Authors:  K Numazaki; S Chiba; T Moroboshi; T Kudoh; T Yamanaka; T Nakao
Journal:  J Clin Pathol       Date:  1985-03       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.