Literature DB >> 7045133

Continuous suture technique in prosthetic aortic valve replacement.

E Hjelms, R Vilhelmsen, I H Rygg.   

Abstract

Among 80 patients having aortic valve replacement using a continuous suture technique the occurrence of periprosthetic leak was 8.8%. There is a statistically significant difference in the occurrence of the periprosthetic leak in patients having pure stenosis (o) of combined stenosis and insufficiency, and patients having pure insufficiency (26%). Continuous suture technique reduces cross clamp time and by-pass time significantly but should be used routinely only in stenotic lesions. In pure insufficiency the method of suture should be considered separately in each case. Interrupted suture technique should be used if one or more of the known factors predisposing to perivalvular leak are present.

Entities:  

Mesh:

Year:  1982        PMID: 7045133

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  6 in total

1.  Continuous Suture Technique for Aortic Valve Replacement: Technical Considerations and Controversies.

Authors:  Sotiris C Stamou; Ellie A Moeller; Marcos A Nores
Journal:  Int J Angiol       Date:  2019-01-28

2.  Multicentre, propensity-matched study to evaluate long-term impact of implantation technique in isolated aortic valve replacement on mortality and incidence of redo surgery.

Authors:  Yama Haqzad; Mahmoud Loubani; Mubarak Chaudhry; Priyadharshanan Ariyaratnam; Norman Briffa
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-02-17

3.  Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography.

Authors:  A Ionescu; A G Fraser; E G Butchart
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

4.  Non infective severe aortic paravalvular leakage 7 years after surgery: the role of suture technique.

Authors:  Marco Agrifoglio; Sara Filippini; Maurizio Roberto; Marco Zanobini; Luisa Gregorini; Francesco Alamanni
Journal:  J Cardiothorac Surg       Date:  2011-04-23       Impact factor: 1.637

5.  Aortic valve replacement using continuous suture technique in patients with aortic valve disease.

Authors:  Jong Bum Choi; Jong Hun Kim; Hyun Kyu Park; Kyung Hwa Kim; Min Ho Kim; Ja Hong Kuh; Jung Ku Jo
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2013-08-06

6.  A rare case of suture material obstructing the closure mechanism of a prosthetic aortic valve: a case report.

Authors:  Emaddin S Kidher; Ryan Perera; Christopher Rao; Syed M Rehman; Nilesh Sutaria; Thanos Athanasiou
Journal:  Cases J       Date:  2009-12-02
  6 in total