Contamination of mechanical ventilators with tubing changes every 24 or 48 hours.

D E Craven, M G Connolly, D A Lichtenberg, P J Primeau, W R McCabe.   

Abstract

We studied the contamination of ventilator circuits in order to assess the need for daily changes of tubing. Patients requiring continuous mechanical ventilation were randomly selected for tubing changes at 24 hours (Group 1) or at 48 hours (Group 2). Samples of inspiratory-phase gas from ventilators with standardized settings were cultured according to the tube-broth method of Edmondson and Sanford. The frequency of positive cultures from 128 ventilators in Group 1 (30 per cent) was not significantly different from that for 112 ventilators in Group 2 (32 per cent). Gram-negative bacteria were most frequently isolated from patient's sputum and ventilator inspiratory-phase gas, but no species predominated in either group of patients. Further studies performed with the Aerotest and Andersen air samplers confirmed that the levels of inspiratory-phase-gas contamination were low in both groups. In addition, quantitative analysis of colonization of the tubing demonstrated no significant increase in colonization between 24 and 48 hours. The absence of a significant difference in inspiratory-phase-gas contamination or tubing colonization suggests that ventilator tubing need be changed only every 48 hours.

Entities:  

Mesh:

Year:  1982        PMID: 7043269     DOI: 10.1056/NEJM198206243062501

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  12 in total

Review 1.  Nosocomial pneumonia: epidemiology and infection control.

Authors:  D E Craven; K A Steger; L M Barat; R A Duncan
Journal:  Intensive Care Med       Date:  1992       Impact factor: 17.440

Review 2.  Nursing home-associated pneumonia, hospital-acquired pneumonia and ventilator-associated pneumonia: the contribution of dental biofilms and periodontal inflammation.

Authors:  Krishnan Raghavendran; Joseph M Mylotte; Frank A Scannapieco
Journal:  Periodontol 2000       Date:  2007       Impact factor: 7.589

3.  Infection control practices in intensive care units of 14 European countries. The EURO.NIS Study Group.

Authors:  M L Moro; O B Jepsen
Journal:  Intensive Care Med       Date:  1996-09       Impact factor: 17.440

4.  Microbial burdens in disposable and nondisposable ventilator circuits used for 24 and 48 h in intensive care units.

Authors:  B Malecka-Griggs; C Kennedy; B Ross
Journal:  J Clin Microbiol       Date:  1989-03       Impact factor: 5.948

5.  Early onset pneumonia: a multicenter study in intensive care units.

Authors:  M Langer; M Cigada; M Mandelli; P Mosconi; G Tognoni
Journal:  Intensive Care Med       Date:  1987       Impact factor: 17.440

Review 6.  Controversies in hospital infection control.

Authors:  F D Daschner; U Frank
Journal:  Eur J Clin Microbiol       Date:  1987-06       Impact factor: 3.267

7.  A clinical assessment of the Mucus Shaver: a device to keep the endotracheal tube free from secretions.

Authors:  Lorenzo Berra; Andrea Coppadoro; Edward A Bittner; Theodor Kolobow; Patrice Laquerriere; Joshua R Pohlmann; Simone Bramati; Joel Moss; Antonio Pesenti
Journal:  Crit Care Med       Date:  2012-01       Impact factor: 7.598

Review 8.  The pathogenesis of ventilator-associated pneumonia: I. Mechanisms of bacterial transcolonization and airway inoculation.

Authors:  R J Estes; G U Meduri
Journal:  Intensive Care Med       Date:  1995-04       Impact factor: 17.440

9.  Useful and useless hygienic techniques in intensive care units.

Authors:  F D Daschner
Journal:  Intensive Care Med       Date:  1985       Impact factor: 17.440

10.  Direct dilution sampling, quantitation, and microbial assessment of open-system ventilation circuits in intensive care units.

Authors:  B Malecka-Griggs; D J Reinhardt
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.