Literature DB >> 7039872

A fluorescence immunoassay for soluble antigens employing flow cytometric detection.

P J Lisi, C W Huang, R A Hoffman, J W Teipel.   

Abstract

A "sandwich" fluorescence immunoassay is described which does not require the physical separation of bound from free label. Antibody coated microspheres, sample and fluorescent antibody are reacted together as in a conventional 'sandwich' immunoassay except that separation and washing steps are omitted. After the reaction is completed, the suspension is introduced directly into a flow cytometer equipped with a laser light source and both fluorescent and scattered light detection capabilities. By gating fluorescence light accumulation on scattered light pulses, particles associated fluorescence may be selectively measured. The system was evaluated in a model immunoassay for human immunoglobulin (hIgG), employing anti-hIgG coated microspheres (1--5 micrometer and 40--50 micrometer polyacrylamide beads and 30--40 micrometer dextran beads), fluorescein-labeled rabbit anti-hIgG and a Spectrum III flow cytometer. Sensitivities of 10 ng/ml and intra-assay precisions of 2--10% were achieved in a serum matrix. The approach potentially provides a general nonseparation immunoassay format for quantitatively measuring both small and large molecular weight soluble antigens, as well as cell surface antigens.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7039872     DOI: 10.1016/0009-8981(82)90153-x

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Integrated dielectrophoretic and surface plasmonic platform for million-fold improvement in the detection of fluorescent events.

Authors:  Logeeshan Velmanickam; Michael Fondakowski; Ivan T Lima; Dharmakeerthi Nawarathna
Journal:  Biomicrofluidics       Date:  2017-08-22       Impact factor: 2.800

2.  Flow cytometric microsphere-based immunoassay: analysis of secreted cytokines in whole-blood samples from asthmatics.

Authors:  C Camilla; L Mély; A Magnan; B Casano; S Prato; S Debono; F Montero; J P Defoort; M Martin; V Fert
Journal:  Clin Diagn Lab Immunol       Date:  2001-07

3.  Flow cytometric measurement of immunoglobulin E to natural latex proteins.

Authors:  P L Kwittken; N A Pawlowski; S K Sweinberg; S D Douglas; D E Campbell
Journal:  Clin Diagn Lab Immunol       Date:  1994-03

4.  MULT1-Encoding DNA Alleviates Schistosomiasis-Associated Hepatic Fibrosis via Modulating Cellular Immune Response.

Authors:  Lu Yang; Shengjun Lu; Li Sun; Yalan Cao; Qi Wang; Anni Song; Ru Zhu; Wenqi Liu
Journal:  J Inflamm Res       Date:  2022-07-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.