Literature DB >> 11427426

Flow cytometric microsphere-based immunoassay: analysis of secreted cytokines in whole-blood samples from asthmatics.

C Camilla1, L Mély, A Magnan, B Casano, S Prato, S Debono, F Montero, J P Defoort, M Martin, V Fert.   

Abstract

The ability of flow cytometry to resolve multiple parameters was used in a microsphere-based flow cytometric assay for the simultaneous determination of several cytokines in a sample. The flow cytometer microsphere-based assay (FMBA) for cytokines consists of reagents and dedicated software, specifically designed for the quantitative determination of cytokines. We have made several improvements in the multiplex assay: (i) dedicated software specific for the quantitative multiplex assay that processes data automatically, (ii) a stored master calibration curve with a two-point recalibration to adjust the stored curve periodically, and (iii) an internal standard to normalize the detection step in each sample. Overall analytical performance, including sensitivity, reproducibility, and dynamic range, was investigated for interleukin-4 (IL-4), IL-6, IL-10, IL-12, gamma interferon (IFN-gamma), and tumor necrosis factor alpha. These assays were found to be reproducible and accurate, with a sensitivity in the picograms-per-milliliter range. Results obtained with FMBA correlate well with commercial enzyme-linked immunosorbent assay data (r > 0.98) for all cytokines assayed. This multiplex assay was applied to the determination of cytokine profiles in whole blood from atopic and nonatopic patients. Our results show that atopic subjects' blood produces more IL-4 (P = 0.003) and less IFN-gamma (P = 0.04) than the blood of nonatopic subjects. However, atopic asthmatic subjects' blood produces significantly more IFN-gamma than that of atopic nonasthmatic subjects (P = 0.03). The results obtained indicate that the FMBA technology constitutes a powerful system for the quantitative, simultaneous determination of secreted cytokines in immune diseases.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11427426      PMCID: PMC96142          DOI: 10.1128/CDLI.8.4.776-784.2001

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  29 in total

1.  Simultaneous detection of antibodies to cytomegalovirus and herpes simplex virus by using flow cytometry and a microsphere-based fluorescence immunoassay.

Authors:  T M McHugh; R C Miner; L H Logan; D P Stites
Journal:  J Clin Microbiol       Date:  1988-10       Impact factor: 5.948

2.  Amplified flow-cytometric separation-free fluorescence immunoassays.

Authors:  G C Saunders; J H Jett; J C Martin
Journal:  Clin Chem       Date:  1985-12       Impact factor: 8.327

3.  A fluorescence immunoassay for soluble antigens employing flow cytometric detection.

Authors:  P J Lisi; C W Huang; R A Hoffman; J W Teipel
Journal:  Clin Chim Acta       Date:  1982-04-08       Impact factor: 3.786

4.  Allergic and nonallergic asthmatics have distinct patterns of T-cell activation and cytokine production in peripheral blood and bronchoalveolar lavage.

Authors:  C Walker; E Bode; L Boer; T T Hansel; K Blaser; J C Virchow
Journal:  Am Rev Respir Dis       Date:  1992-07

5.  Simultaneous detection of multiplex-amplified human immunodeficiency virus type 1 RNA, hepatitis C virus RNA, and hepatitis B virus DNA using a flow cytometer microsphere-based hybridization assay.

Authors:  J P Defoort; M Martin; B Casano; S Prato; C Camilla; V Fert
Journal:  J Clin Microbiol       Date:  2000-03       Impact factor: 5.948

6.  Predominant TH2-like bronchoalveolar T-lymphocyte population in atopic asthma.

Authors:  D S Robinson; Q Hamid; S Ying; A Tsicopoulos; J Barkans; A M Bentley; C Corrigan; S R Durham; A B Kay
Journal:  N Engl J Med       Date:  1992-01-30       Impact factor: 91.245

7.  Cytokines in symptomatic asthma airways.

Authors:  D H Broide; M Lotz; A J Cuomo; D A Coburn; E C Federman; S I Wasserman
Journal:  J Allergy Clin Immunol       Date:  1992-05       Impact factor: 10.793

8.  Balance between proinflammatory cytokines and their inhibitors in bronchial lavage from patients with status asthmaticus.

Authors:  I Tillie-Leblond; J Pugin; C H Marquette; C Lamblin; F Saulnier; A Brichet; B Wallaert; A B Tonnel; P Gosset
Journal:  Am J Respir Crit Care Med       Date:  1999-02       Impact factor: 21.405

9.  Immunometric assay by flow cytometry using mixtures of two particle types of different affinity.

Authors:  T Lindmo; O Børmer; J Ugelstad; K Nustad
Journal:  J Immunol Methods       Date:  1990-02-09       Impact factor: 2.303

10.  Production of chemokines and proinflammatory and antiinflammatory cytokines by human alveolar macrophages activated by IgE receptors.

Authors:  P Gosset; I Tillie-Leblond; S Oudin; O Parmentier; B Wallaert; M Joseph; A B Tonnel
Journal:  J Allergy Clin Immunol       Date:  1999-02       Impact factor: 10.793

View more
  4 in total

1.  Validation and comparison of luminex multiplex cytokine analysis kits with ELISA: determinations of a panel of nine cytokines in clinical sample culture supernatants.

Authors:  Nefertiti C dupont; Kehui Wang; Pathik D Wadhwa; Jennifer F Culhane; Edward L Nelson
Journal:  J Reprod Immunol       Date:  2005-08       Impact factor: 4.054

Review 2.  Multiplexed and microparticle-based analyses: quantitative tools for the large-scale analysis of biological systems.

Authors:  John P Nolan; Francis Mandy
Journal:  Cytometry A       Date:  2006-05       Impact factor: 4.355

3.  Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells.

Authors:  Wilco de Jager; Henk te Velthuis; Berent J Prakken; Wietse Kuis; Ger T Rijkers
Journal:  Clin Diagn Lab Immunol       Date:  2003-01

4.  Polymeric Coating of Silica Microspheres for Biological Applications: Suppression of Non-Specific Binding and Functionalization with Biomolecules.

Authors:  Dario Brambilla; Alessandro Mussida; Anna M Ferretti; Laura Sola; Francesco Damin; Marcella Chiari
Journal:  Polymers (Basel)       Date:  2022-02-14       Impact factor: 4.329

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.