Literature DB >> 7007432

Detection of bacteriuria: manual screening test and early examination of agar plates.

P R Murray, A C Niles.   

Abstract

We assessed two procedures for the initial processing of urine specimens: (i) manual screening of urine samples by inoculation into tryptic soy broth and incubation for 3 to 6 h, and (ii) examination of agar plates inoculated with urine and incubated for 4 to 6 h. Of the urine samples with greater than 10(5) colony-forming units per ml, 73.6 and 90.1% were detected with the broth cultures after 3 and 6 h of incubation, respectively. The organisms not detected at 6 h were Corynebacterium spp., Lactobacillus spp., and one of six isolates of yeasts. When inoculated plates were examined for growth, 53.3 and 80.0% of the specimens with greater than 10(5) colony-forming units per ml were detected after 4 and 6 h of incubation, respectively. Of the cultures with significant growth of Enterobacteriaceae or Pseudomonas spp., 95% were detected on the plates after 6 h of incubation.

Entities:  

Mesh:

Year:  1981        PMID: 7007432      PMCID: PMC273727          DOI: 10.1128/jcm.13.1.85-88.1981

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  19 in total

1.  Accuracy of Kirby-Bauer susceptibility tests read at 4, 8, and 12 hours of incubation: comparison with readings at 18 to 20 hours.

Authors:  R M Kluge
Journal:  Antimicrob Agents Chemother       Date:  1975-08       Impact factor: 5.191

2.  Clinical laboratory evaluation of automated microbial detection/identification system in analysis of clinical urine specimens.

Authors:  H D Isenberg; T L Gavan; A Sonnenwirth; W I Taylor; J A Washington
Journal:  J Clin Microbiol       Date:  1979-08       Impact factor: 5.948

3.  Automated screening for bacteriuria.

Authors:  R P Human; G D Rowe
Journal:  Med Lab Sci       Date:  1978-07

4.  Detection of bacteriuria by automated electrical impedance monitoring in a clinical microbiology laboratory.

Authors:  R Throm; S Specter; R Strauss; H Friedman
Journal:  J Clin Microbiol       Date:  1977-09       Impact factor: 5.948

5.  Rapid screening for significant bacteriuria using a Coulter Counter.

Authors:  R Smither
Journal:  J Clin Pathol       Date:  1977-12       Impact factor: 3.411

6.  Rapid detection of urinary infections by microscopic observation of growing cultures.

Authors:  P Chadwick; F Avila
Journal:  Can Med Assoc J       Date:  1968-11-09       Impact factor: 8.262

7.  A rapid (4--6-hour) urine-culture system for direct identification and direct antimicrobial susceptibility testing.

Authors:  P A Heinze; L D Thrupp; C R Anselmo
Journal:  Am J Clin Pathol       Date:  1979-02       Impact factor: 2.493

Review 8.  Genitourinary fungal infections.

Authors:  S Michigan
Journal:  J Urol       Date:  1976-10       Impact factor: 7.450

9.  Rapid semiautomated screening and processing of urine specimens.

Authors:  R D Jenkins; D C Hale; J M Matsen
Journal:  J Clin Microbiol       Date:  1980-03       Impact factor: 5.948

10.  Incidence and significance of candiduria.

Authors:  P K Goldberg; P J Kozinn; G J Wise; N Nouri; R B Brooks
Journal:  JAMA       Date:  1979-02-09       Impact factor: 56.272

View more
  6 in total

1.  Processing urine specimens: overnight versus two-day incubation.

Authors:  F Soriano; C Ponte
Journal:  J Clin Microbiol       Date:  1992-11       Impact factor: 5.948

2.  Evaluation of microbiological processing of urine specimens: comparison of overnight versus two-day incubation.

Authors:  P Murray; P Traynor; D Hopson
Journal:  J Clin Microbiol       Date:  1992-06       Impact factor: 5.948

3.  Comparison of the automicrobic system, acridine orange-stained smears, and gram-stained smears in detecting bacteriuria.

Authors:  B A Lipsky; J J Plorde; F C Tenover; F P Brancato
Journal:  J Clin Microbiol       Date:  1985-08       Impact factor: 5.948

4.  Evaluation of incubation times for urine cultures.

Authors:  R Cavagnolo
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

5.  Clinical laboratory evaluation of a urine screening device.

Authors:  M A Pfaller; C A Baum; A C Niles; P R Murray
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

6.  Rapid method for identification and susceptibility testing of Escherichia coli bacteriuria.

Authors:  F E Dennstedt; C E Stager; J R Davis
Journal:  J Clin Microbiol       Date:  1983-07       Impact factor: 5.948

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.