Literature DB >> 6991525

Rapid, reproducible enzyme immunoassay for gentamicin.

D Phaneuf, E Francke, H C Neu.   

Abstract

An enzyme immunoassay for gentamicin utilizing glucose-6-phosphate dehydrogenase was compared to the radioimmunoassay. The enzyme immunoassay for gentamicin was accurate, specific, and easily performed. It offers an ulternative method to assay aminoglycosides and could be used in institutions using enzyme immunoassay to assay other drugs.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6991525      PMCID: PMC273376          DOI: 10.1128/jcm.11.3.266-269.1980

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  10 in total

1.  Adaptation of "EMIT" technique for serum phenobarbital and diphenylhydantoin assays to the miniature centrifugal analyzer.

Authors:  S D Brunk; T P Hadjiioannou; S I Hadjiioannou; H V Malmstadt
Journal:  Clin Chem       Date:  1976-06       Impact factor: 8.327

2.  Assay of phenytoin: adaptation of "EMIT" to the centrifugal analyzer.

Authors:  P R Finley; R J Williams; J M Byers
Journal:  Clin Chem       Date:  1976-06       Impact factor: 8.327

3.  Enzymatic assay for gentamicin and related aminoglycoside antibiotics.

Authors:  R K Holmes; J P Sanford
Journal:  J Infect Dis       Date:  1974-05       Impact factor: 5.226

4.  A rapid chemical assay for gentamicin.

Authors:  D H Smith; B Van Otto; A L Smith
Journal:  N Engl J Med       Date:  1972-03-16       Impact factor: 91.245

5.  Radioimmunoassay of an antibiotic: gentamicin.

Authors:  J E Lewis; J C Nelson; H A Elder
Journal:  Nat New Biol       Date:  1972-10-18

6.  "Homogeneous" enzyme immunoassay. A new immunochemical technique.

Authors:  K E Rubenstein; R S Schneider; E F Ullman
Journal:  Biochem Biophys Res Commun       Date:  1972-05-26       Impact factor: 3.575

7.  Quality control of serum gentamicin assays--experience of national surveys.

Authors:  D S Reeves; M J Bywater
Journal:  J Antimicrob Chemother       Date:  1975-03       Impact factor: 5.790

8.  Rapid microassay of gentamicin, kanamycin, neomycin, streptomycin, and vancomycin in serum or plasma.

Authors:  L D Sabath; J I Casey; P A Ruch; L L Stumpf; M Finland
Journal:  J Lab Clin Med       Date:  1971-09

Review 9.  Gentamicin in 1978.

Authors:  G B Appel; H C Neu
Journal:  Ann Intern Med       Date:  1978-10       Impact factor: 25.391

Review 10.  Why monitor serum levels of gentamicin?

Authors:  M Barza; M Lauermann
Journal:  Clin Pharmacokinet       Date:  1978 May-Jun       Impact factor: 6.447

  10 in total
  14 in total

1.  Comparison of the Beckman Auto ICS and the Syva Autolab 6000 for determination of gentamicin levels in serum.

Authors:  R H Glew; R A Pavuk
Journal:  J Clin Microbiol       Date:  1985-01       Impact factor: 5.948

2.  Measurement of levels of aminoglycosides and vancomycin in serum in the presence of new beta-lactam antibiotics.

Authors:  S B Calderwood; C C Tung; E Jackson
Journal:  J Clin Microbiol       Date:  1984-05       Impact factor: 5.948

3.  An evaluation of gentamicin EMIT--its performance on the Kem-O-Mat and its role in the small laboratory.

Authors:  R G Masterton; R E Tettmar; P W Strike; S Williams
Journal:  J Clin Pathol       Date:  1983-11       Impact factor: 3.411

4.  Correlation of bioluminescent assay of gentamicin in serum with agar diffusion assay, latex agglutination inhibition card test, enzyme immunoassay, and fluorescence immunoassay.

Authors:  L Nilsson
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

5.  Potential liabilities of gentamicin homogeneous enzyme immunoassay.

Authors:  L G Carlson; C J Delaney; J J Plorde
Journal:  Antimicrob Agents Chemother       Date:  1982-01       Impact factor: 5.191

6.  Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin.

Authors:  C J Delaney; K E Opheim; A L Smith; J J Plorde
Journal:  Antimicrob Agents Chemother       Date:  1982-01       Impact factor: 5.191

7.  Comparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.

Authors:  D J Pohlod; L D Saravolatz; M M Somerville
Journal:  J Clin Microbiol       Date:  1984-11       Impact factor: 5.948

8.  Comparative analysis of two rapid, automated methods for determining aminoglycoside levels.

Authors:  J H Ngui-Yen; P W Doyle; J A Smith
Journal:  J Clin Microbiol       Date:  1984-11       Impact factor: 5.948

9.  Rapid, reproducible enzyme immunoassay for tobramycin.

Authors:  E L Francke; S Srinivasan; P Labthavikul; H C Neu
Journal:  J Clin Microbiol       Date:  1981-01       Impact factor: 5.948

10.  Gentamicin interval in newborn infants as determined by renal function and postconceptional age.

Authors:  L P Brion; A R Fleischman; G J Schwartz
Journal:  Pediatr Nephrol       Date:  1991-11       Impact factor: 3.714

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.