Literature DB >> 6987233

Implant-bone interface characteristics of bioglass dental implants.

A M Weinstein, J J Klawitter, S D Cook.   

Abstract

Three-dimensional finite element analysis (FEA) has been used to determine the implant-bone interface characteristics of bioglass dental implants. The results of the FEA were verified by comparison with the results of mechanical testing performed on animal implant specimens. The results of the study showed that the assumption of a discontinuous change of elastic properties at the bone-implant interface was a poor assumption for the bioglass implants. Interface elastic moduli of 354.0, 155.0, and 47.0 MPa for conditions of 25, 50, and 100% tissue attachment were determined for the bioglass implants.

Mesh:

Substances:

Year:  1980        PMID: 6987233     DOI: 10.1002/jbm.820140104

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  12 in total

1.  Conservative restoration of severely damaged endodontically treated premolar teeth: a FEM study.

Authors:  Öznur Eraslan; Oğuz Eraslan; Gürcan Eskitaşcıoğlu; Sema Belli
Journal:  Clin Oral Investig       Date:  2010-03-18       Impact factor: 3.573

2.  The story of Bioglass.

Authors:  Larry L Hench
Journal:  J Mater Sci Mater Med       Date:  2006-11-22       Impact factor: 3.896

3.  The finite element analysis of the effect of ferrule height on stress distribution at post-and-core-restored all-ceramic anterior crowns.

Authors:  Oğuz Eraslan; Filiz Aykent; M Tolga Yücel; Serhan Akman
Journal:  Clin Oral Investig       Date:  2008-08-12       Impact factor: 3.573

4.  The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis.

Authors:  Oğuz Eraslan; Ozgür Inan
Journal:  Clin Oral Investig       Date:  2009-06-20       Impact factor: 3.573

5.  Effect of revascularisation and apexification procedures on biomechanical behaviour of immature maxillary central incisor teeth: a three-dimensional finite element analysis study.

Authors:  Persis Anthrayose; Ruchika Roongta Nawal; Seema Yadav; Sangeeta Talwar; Sudha Yadav
Journal:  Clin Oral Investig       Date:  2021-04-26       Impact factor: 3.573

6.  Stress analysis of a fixed implant-supported denture by the finite element method (FEM) when varying the number of teeth used as abutments.

Authors:  Marcos Daniel Septímio Lanza; Paulo Isaías Seraidarian; Wellington Correa Jansen; Marcos Dias Lanza
Journal:  J Appl Oral Sci       Date:  2011 Nov-Dec       Impact factor: 2.698

7.  Long-term in vivo two-photon imaging of the neuroinflammatory response to intracortical implants and micro-vessel disruptions in awake mice.

Authors:  Qianru Yang; Alberto L Vazquez; Xinyan Tracy Cui
Journal:  Biomaterials       Date:  2021-08-12       Impact factor: 15.304

8.  The influence of the bone-implant interface stiffness on stress profiles surrounding Al2O3 and carbon dental implants.

Authors:  C J Lavernia; S D Cook; A M Weinstein; J J Klawitter
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

9.  Bioglass: A novel biocompatible innovation.

Authors:  Vidya Krishnan; T Lakshmi
Journal:  J Adv Pharm Technol Res       Date:  2013-04

10.  Experimentally determined mechanical properties of, and models for, the periodontal ligament: critical review of current literature.

Authors:  Ted S Fill; Jason P Carey; Roger W Toogood; Paul W Major
Journal:  J Dent Biomech       Date:  2011-04-05
View more