Literature DB >> 696281

Unstable trochanteric fractures treated with the sliding screw-plate system. A biomechanical study of unstable trochanteric fractures. III.

J S Jensen, E Tøndevold, N Mossing.   

Abstract

Eighty unstable trochanteric fractures were treated with the sliding screw-plate system. Early weight-bearing was encouraged and mobilization was obtained within the first week in 47 per cent of the cases (37/78). Technical complications were encountered in 5 per cent of the patients (4/76) but none required re-operation. Telescoping of the screw occurred in 49 per cent (37/76). Through this secondary fracture impaction a stable load transmission system was established. Fracture union in the postoperative position was obtained in 49 per cent of the patients (37/76) and non-union did not occur.

Entities:  

Mesh:

Year:  1978        PMID: 696281     DOI: 10.3109/17453677809050094

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  11 in total

1.  Treatment of subtrochanteric fractures. A comparison of the Gamma nail and the dynamic hip screw: short-term outcome in 58 patients.

Authors:  I Saarenpää; T Heikkinen; P Jalovaara
Journal:  Int Orthop       Date:  2006-04-22       Impact factor: 3.075

2.  Biomechanical analysis of the dynamic hip screw in the treatment of intertrochanteric fractures.

Authors:  C C Wu; C H Shih
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Primary hemiarthroplasty for unstable osteoporotic intertrochanteric fractures in the elderly: A retrospective case series.

Authors:  Kh Sancheti; Pk Sancheti; Ak Shyam; S Patil; Q Dhariwal; R Joshi
Journal:  Indian J Orthop       Date:  2010-10       Impact factor: 1.251

4.  Serial change of sliding in intertrochanteric femoral fractures treated with sliding screw system.

Authors:  K Nakata; K Ohzono; K Hiroshima; K Toge
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

5.  Sliding-screw plate fixation of proximal femoral fractures: radiographic assessment.

Authors:  D J Sartoris; R Kerr; T Goergen; D Resnick
Journal:  Skeletal Radiol       Date:  1985       Impact factor: 2.199

6.  Sliding hip screws and medial displacement osteotomy.

Authors:  D Nunn
Journal:  J R Soc Med       Date:  1988-03       Impact factor: 18.000

7.  Use of Ender's nails in unstable trochanteric femoral fractures.

Authors:  C H Marsh
Journal:  J R Soc Med       Date:  1983-07       Impact factor: 18.000

8.  Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation.

Authors:  George K Kouvidis; Mark B Sommers; Peter V Giannoudis; Pavlos G Katonis; Michael Bottlang
Journal:  J Orthop Surg Res       Date:  2009-05-18       Impact factor: 2.359

9.  Is there a difference in the positioning of sliding screws between stable and unstable extracapsular fractures?

Authors:  Pedro José Labronici; Rodrigo Freitas da Silva; Ana Maria Santos Viana; Saulo Santos Blunck; José Sergio Franco; Sergio Ricardo Neto; Robinson Esteves Santos Pires; Roberto Canto
Journal:  Rev Bras Ortop       Date:  2015-02-24

Review 10.  Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate.

Authors:  Bjarke Viberg; Katrine M V Rasmussen; Søren Overgaard; Cecilia Rogmark
Journal:  Acta Orthop       Date:  2017-03-13       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.