Literature DB >> 6927201

Prospective tissue-mimicking materials for use in NMR imaging phantoms.

E L Madsen, G D Fullerton.   

Abstract

Water-based proteinaceous gels, which--with appropriate additives--are stable with time and possess a high melting point, have been used as base materials in ultrasonically tissue-mimicking materials. In the present work, versions of these gels having various concentrations of glycerol and graphite particles were studied regarding their NMR T1 and T2 dependencies at a proton Larmor frequency of 10.7 MHz. It has been found that T1 depends primarily on the concentration of glycerol and T2 depends primarily on the graphite particle concentration. Also, the ranges of T1 and T2 likely span those which exist for soft tissue parenchymae. Thus, these materials are good candidates for use as NMR tissue-mimicking materials. T1 and T2 also vary with gelatin concentration. The latter fact, together with the strong dependence of T2 on graphite concentration, mean that effective contrast-resolution phantoms and anthropomorphic phantoms with stable T1 and T2 distributions can be produced.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6927201     DOI: 10.1016/0730-725x(82)90204-1

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  False cerebral activation on BOLD functional MR images: study of low-amplitude motion weakly correlated to stimulus.

Authors:  A S Field; Y F Yen; J H Burdette; A D Elster
Journal:  AJNR Am J Neuroradiol       Date:  2000-09       Impact factor: 3.825

2.  Proposal of a Lab Bench for the Unobtrusive Monitoring of the Bladder Fullness with Bioimpedance Measurements.

Authors:  Valentin Gaubert; Hayriye Gidik; Vladan Koncar
Journal:  Sensors (Basel)       Date:  2020-07-17       Impact factor: 3.576

3.  Multimodal phantom of liver tissue.

Authors:  Magdalena K Chmarra; Rune Hansen; Ronald Mårvik; Thomas Langø
Journal:  PLoS One       Date:  2013-05-14       Impact factor: 3.240

4.  MRI phantoms - are there alternatives to agar?

Authors:  Alexandra Hellerbach; Verena Schuster; Andreas Jansen; Jens Sommer
Journal:  PLoS One       Date:  2013-08-05       Impact factor: 3.240

5.  Quality assurance of registration of CT and MRI data sets for treatment planning of radiotherapy for head and neck cancers.

Authors:  Craig S Moore; Gary P Liney; Andrew W Beavis
Journal:  J Appl Clin Med Phys       Date:  2004-01-01       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.