Literature DB >> 6906155

Automatic (Octopus) and manual (Goldmann) perimetry in glaucoma.

U Schmied.   

Abstract

Of 115 patients with chronic open angle glaucoma or suspected glaucoma 115 eyes were subjected to a visual field examination with the manual Goldmann perimeter and the automatic Octopus perimeter. In 84.4 +/- 8.9% the automaton detected more visual field loss, including 27.8 +/- 10.9% of the eyes where no visual field loss was found by the manual perimetry. Since some eyes with normal fields on manual perimetry and abnormal fields detected by automatic perimetry remained abnormal on retesting, it is assumed that scotomas found by automatic perimetry and not shown by manual perimetry constitute false-negative manual fields rather than false-positive automatic fields.

Entities:  

Mesh:

Year:  1980        PMID: 6906155     DOI: 10.1007/bf00417545

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  6 in total

1.  Static perimetry: accuracy and fluctuations.

Authors:  H Bebie; F Fankhauser; J Spahr
Journal:  Acta Ophthalmol (Copenh)       Date:  1976-07

2.  [Automation of the perimeter. I. Application of a computer-regulated perimeter (author's transl)].

Authors:  J Spahr
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1973-11-06

3.  A modification of the Armaly visual field screening technique for glaucoma.

Authors:  W J Rock; S M Drance; R W Morgan
Journal:  Can J Ophthalmol       Date:  1971-10       Impact factor: 1.882

4.  [Practical experiences with the Octopus automatic perimeter (author's transl)].

Authors:  J Spahr; F Fankhauser; A Jenni; H Bebie
Journal:  Klin Monbl Augenheilkd       Date:  1978-04       Impact factor: 0.700

5.  Automatic perimetry in glaucoma visual field screening. A clinical study.

Authors:  A Heijl
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1976-07-26

6.  Some aspects of the automation of perimetry.

Authors:  F Frankhauser; J Spahr; H Bebie
Journal:  Surv Ophthalmol       Date:  1977 Sep-Oct       Impact factor: 6.048

  6 in total
  9 in total

1.  Full threshold versus quantification of defects for visual field testing in glaucoma.

Authors:  W C Stewart; M B Shields; A R Ollie
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1989       Impact factor: 3.117

2.  Temporal visual field in glaucoma: a re-evaluation in the automated perimetry era.

Authors:  G E Pennebaker; W C Stewart
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

3.  Examination of the retinal nerve fiber layer in the recognition of early glaucoma damage.

Authors:  H A Quigley
Journal:  Trans Am Ophthalmol Soc       Date:  1986

4.  The qualitative comparative analysis of the visual field using computer assisted, semi-automated and manual instrumentation: II. Statistical analysis.

Authors:  J M Wild; J G Flanagan; D A Barnes; B A Gilmartin; P A Good; S J Crews
Journal:  Doc Ophthalmol       Date:  1984-12-15       Impact factor: 2.379

5.  Manipulation of sensitivity in visual field investigation.

Authors:  D A Barnes; J M Wild; J G Flanagan; P A Good; S J Crews
Journal:  Doc Ophthalmol       Date:  1985-06-30       Impact factor: 2.379

6.  Analytic approaches to the interpretation of automated threshold perimetric data for the diagnosis of early glaucoma.

Authors:  A Sommer; C Duggan; C Auer; H Abbey
Journal:  Trans Am Ophthalmol Soc       Date:  1985

7.  Changes of glaucomatous field defects. Degree of accuracy of measurements with the automatic perimeter Octopus.

Authors:  B Gloor; U Schmied; A Faessler
Journal:  Int Ophthalmol       Date:  1980-12       Impact factor: 2.031

8.  Performance of computer assisted perimeters.

Authors:  E L Greve
Journal:  Doc Ophthalmol       Date:  1982-12-01       Impact factor: 2.379

9.  Effect of retinal nerve fibre loss on the optic nerve head configuration in early glaucoma.

Authors:  P J Airaksinen; H I Alanko
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1983       Impact factor: 3.117

  9 in total