| Literature DB >> 6893446 |
Abstract
High performance liquid chromatographic (HPLC) procedures were utilized for the rapid and efficient separation and characterization of the aromatic heptaene macrolide group of antifungal antibiotics. The instrument utilized a 350 nm phosphor converted ultraviolet detector and a mu Bondapak C18 column packing. Optimum resolution of eleven commercial aromatic heptaene macrolide preparations was obtained with solvent systems consisting of mixtures of acetonitrile and 0.05 M aqueous sodium citrate buffer, pH 5.3. The presence of two distinct types of aromatic heptaene macrolides with numerous well-defined individual components has been established.Entities:
Mesh:
Substances:
Year: 1980 PMID: 6893446 DOI: 10.7164/antibiotics.33.591
Source DB: PubMed Journal: J Antibiot (Tokyo) ISSN: 0021-8820 Impact factor: 2.649