Literature DB >> 6884379

A practical approach to the hepatobiliary kinetics of 99mTc-HIDA. Clinical validation of the method and a preliminary report on its use for parametric imaging.

G Galli, C L Maini, M Salvatori, F Andreasi.   

Abstract

99mTc-diethyl-HIDA cholescintigraphy was performed on 24 patients with histologically proven liver disease and on 10 normal adult subjects. Liver mass transport of HIDA was interpreted with the aid of a probabilistic model, assuming that the tracer particles undergo mixed random walks with drifts. The radiohepatograms were thus fitted with a gamma-variate function and the fitting parameters were evaluated as estimates of the severity of the disease. These parameters, together with the transit times, were also used to generate parametric images of liver function. The advantages of this approach are discussed and the following conclusions are drawn: (1) The gamma-fit is highly satisfactory with any type of experimental curve (0.98 less than r less than 1). (2) The parameters derived from the gamma-fit make it possible to objectively assess the extent of liver functional impairment. (3) Parametric imaging of the liver mass transport of HIDA is easily implemented, but still more experience is needed to assess its impact on patient care.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6884379     DOI: 10.1007/bf00253754

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  13 in total

1.  INDICATOR TRANSIT TIME CONSIDERED AS A GAMMA VARIATE.

Authors:  H K THOMPSON; C F STARMER; R E WHALEN; H D MCINTOSH
Journal:  Circ Res       Date:  1964-06       Impact factor: 17.367

2.  Analysis of the role of indicator technics in quantitation of valvular regurgitation.

Authors:  H R WARNER
Journal:  Circ Res       Date:  1962-03       Impact factor: 17.367

3.  Mathematical considerations of indicator dilution techniques.

Authors:  C W SHEPPARD
Journal:  Minn Med       Date:  1954-02

4.  The dye dilution method for describing the central circulation. An analysis of factors shaping the time-concentration curves.

Authors:  E V NEWMAN; M MERRELL; A GENECIN; C MONGE; W R MILNOR; W P McKEEVER
Journal:  Circulation       Date:  1951-11       Impact factor: 29.690

5.  Computer computations of cardiac output using the gamma function.

Authors:  C F Starmer; D O Clark
Journal:  J Appl Physiol       Date:  1970-02       Impact factor: 3.531

6.  Tracer dilution curves in cardiology and random walk and lognormal distributions.

Authors:  M E Wise
Journal:  Acta Physiol Pharmacol Neerl       Date:  1966

7.  Investigation of the effect of data error in the analysis of biological tracer data from three compartment systems.

Authors:  J Myhill
Journal:  J Theor Biol       Date:  1969-05       Impact factor: 2.691

8.  The quantitative limitations of exponential curve fitting.

Authors:  H I Glass; A C De Garreta
Journal:  Phys Med Biol       Date:  1971-01       Impact factor: 3.609

9.  A mathematical model for the liver uptake and excretion of 99mTc-diethyl IDA.

Authors:  L Gelius; A Skretting; M Aas
Journal:  Eur J Nucl Med       Date:  1981-04

10.  Hepato-biliary scintigraphy and hepatography with Tc-99m diethyl-acetanilido-iminodiacetate in obstructive jaundice.

Authors:  S P Nielsen; J Trap-Jensen; J Lindenberg; M L Nielsen
Journal:  J Nucl Med       Date:  1978-05       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.